Hitachi WJ200-004M Quick Reference Manual page 41

Wj200 series
Hide thumbs Also See for WJ200-004M:
Table of Contents

Advertisement

Monitoring functions
NOTE:. Mark " " in b031=10 shows the accessible parameters when b031 is set "10", high
level access.
Func.
Code
D001
Output frequency monitor
D002
Output current monitor
D003
Rotation direction monitor
Process variable (PV),
D004
PID feedback monitor
Intelligent input
D005
terminal status
Intelligent output
D006
terminal status
"d" Function
Name
Real time display of output frequency
to motor from
0.0 to 400.0Hz
If b163 is set high, output frequency
(F001) can be changed by up/down
key with d001 monitoring.
Filtered display of output current to
motor, range is
0 to 655.3 ampere (~99.9 ampere for
1.5kW and less)
Three different indications:
"F" ...Forward
"o" ...Stop
"r" ...Reverse
Displays the scaled PID process
variable (feedback) value (A075 is
scale factor),
0.00 to 10000
Displays the state of the intelligent
input terminals:
Displays the state of the intelligent
output terminals:
Description
OFF
7
6 5 4
3
2
1
Terminal numbers
Relay
12 11
40
Run
Mode
Edit
% times
constant
ON
ON
OFF
Units
Hz
A