Hitachi WJ200-004M Quick Reference Manual page 63

Wj200 series
Hide thumbs

Advertisement

Func.
Name
Code
Communication error
C076
select
Communication error
C077
time-out
C078
Communication wait time
C081
O input span calibration
C082
OI input span calibration
Thermistor input (PTC)
C085
span calibration
C091
Debug mode enable
C096
Communication selection
C098
EzCOM start adr. of master
C099
EzCOM end adr. of master
C100
EzCOM starting trigger
Up/Down memory mode
C101
selection
"C" Function
Description
Selects inverter response to
communications error.
Five options:
00...Trip
01...Decelerate to a stop and trip
02...Disable
03...Free run stop (coasting)
04...Decelerates to a stop
Sets the communications watchdog
timer period.
Range is 0.00 to 99.99 sec
0.0 = disabled
Time the inverter waits after
receiving a message before it
transmits.
Range is 0. to 1000. ms
Scale factor between the external
frequency command on terminals
L–O (voltage input) and the
frequency output,
range is 0.0 to 200%
Scale factor between the external
frequency command on terminals
L–OI (voltage input) and the
frequency output,
range is 0.0 to 200%
Scale factor of PTC input.
Range is 0.0 to 200%
Displays debug parameters.
Two option codes:
00...Disable
01...Enable <Do not set>
(for factory use)
00...Modbus-RTU
01... EzCOM
02... EzCOM<administrator>
01-08
01-08
00... Input terminal
01... Always
Controls speed setpoint for the
inverter after power cycle.
Two option codes:
00...Clear last frequency (return to
default frequency F001)
01...Keep last frequency adjusted
by UP/DWN
62
Run
Defaults
Mode
Initial data
Edit
02
0.00
0.
msec.
100.0
100.0
100.0
00
00
01
01
00
00
Units
sec.
%
%
%

Advertisement

loading

  Related Manuals for Hitachi WJ200-004M

This manual is also suitable for:

Wj200-007m