Battery Installation - SANYANG INDUSTRY CO. XS125-K Service Manual

Table of Contents

Advertisement

BATTERY
BATTERY REMOVAL AND
INSTALLATION
Remove the right side cover.
Disconnect the battery negative cable first, then the
battery positive cable.
Disconnect the battery band, remove the battery.

BATTERY INSTALLATION

Put the battery on the battery rack.
Install the battery band.
Connect the battery positive cable first, then the
battery negative cable.
Grease terminals with
Install the right side cover.
SPECIFIC GRAVITY TEST
Test each cell by using a hydrometer.
SPECIFIC GRAVITY :
1.260-1.280
Fully charged
1.220 or below
Undercharged
(20℃/68 °F )
NOTE ~
• The battery must be recharged if the specific
gravity is below 1.23.
• The specific gravity varies with the temperature as
shown in the accompanying table.
• Replace the battery if sulfating is evident.
The battery must be replaced if there are pastes
on the bottom of each cell.
WARNING:
The battery electrolyte contains sulfuric acid.
Protect your skin, eyes and clothing. Note the
followings:
1. In case of contact, flush thoroughly with water.
2. In case of drinking, drink mass of water or milk,
and eat the white of an egg or drink vegetable oil.
3. Cover the eyes when operating at short distance,
in case of contact, flush thoroughly with water and
spread of eye-ointment.
4. Keep flames and sparks away from a charging
battery.
5.Place the charging battery in a ventilate area.
LIQUI MOLY terminal grease.