Status Codes; Table 23: Diag. - Status Codes - Redline AN-80i User Manual

Ptp system
Hide thumbs Also See for AN-80i:
Table of Contents

Advertisement

5.5

Status Codes

The AN-80i reports the following conditions using the Status Code field. See
3.3.1: System Status on page 18.
Error Type
Tx Power
RF High Temp.
Warning
RF PLL Lock
Error
PHY lock error
80 MHz PLL lock
error
Firmware
Configuration
Error
70-00072-01-01-DRAFT

Table 23: Diag. - Status Codes

Error #
Description
(Hexadecimal)
0x0001
Power output is less than 10 dBm.
0x0002
The transceiver internal temperature rose above
185F / 85C. The transceiver will shut down for 30
seconds to allow cooling.
0x0010
The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
0x0020
The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
0x0040
The PLL (Phase Locked Loop) section within the
AN-80i experienced an error. Reset the AN-80i.
0x0100
Error detected in the AN-80i configuration file.
Proprietary Redline Communications © 2006
Page 51 of 60
AN-80i
user manual
October 18, 2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents