Reset; Save; Set; Table 11: Cli - Reboot - Redline AN-80i User Manual

Ptp system
Hide thumbs Also See for AN-80i:
Table of Contents

Advertisement

Command
reboot
4.2.4

Reset

Use the reset command to set all AN-80i statistics values to zero.
Command
reset
4.2.5

Save

Use the save command to copy edited parameter settings into non-volatile
memory. See section 5.3: Testing and Saving System Parameters on page 49.
save [option] <Enter>
Command
save
4.2.6

Set

Use the set command to view and/or change a parameter.
View a parameter:
set [field] <Enter>
Change a parameter:
set [field] [value] <Enter>
Command
set
70-00072-01-01-DRAFT
Parameter/Description
Reboot the AN-80i. There are no parameters associated with this
command.
reboot <Enter>
Parameter/Description
stats: Reset the AN-80i statistics counters.
reset stats <Enter>

Table 13: CLI - save

Parameter/Description
config: Save Ethernet, wireless, and user configuration settings.
snmp: Save SNMP settings.
defaultconfig: Overwrite current settings with the factory default
Ethernet, wireless, and SNMP settings.

Table 14: CLI - set

Parameter/Description
adaptmod: Enable or disable the adaptive modulation function.
off - Disable
on - Enable
When enabled, the AN-80i will automatically change the modulation to
the highest setting that can sustain a packet error rate lower than 1x10e-
6. If the packet error rate exceeds 1x10e-6, the system automatically
steps down modulation/code rate (i.e., from 16 QAM 3/4 to 16 QAM 1/2 )
to maintain the wireless link quality.
Proprietary Redline Communications © 2006
Page 39 of 60
user manual

Table 11: CLI - reboot

Table 12: CLI - reset

AN-80i
October 18, 2006