General

System Name: Enter the name for this AN-80i. The name can be any combination
of letters and numbers.
System Details: Enter additional descriptive details about this AN-80i. The
description can be any combination of letters and numbers.
System Location: Enter additional descriptive details about this AN-80i. The
description can be any combination of letters and numbers.
Contact: Enter additional descriptive details about this AN-80i. The description
can be any combination of letters and numbers.
IP Address: Enter the IP address for this AN-80i. The IP address is routable
through the Ethernet port and over the wireless interface.
IP Subnet Mask: Enter the IP subnet mask.
Default Gateway Address: Enter the IP address of the default gateway or router
on the Ethernet segment connected to the AN-80i Ethernet port.
Flow Control Enable: Check this box
(802.3x) on the AN-80i Ethernet port. Enabling this feature allows the AN-80i to
request Ethernet devices to pause transmissions during busy periods.
SNTP Enable: Check this box
feature allows AN-80i systems to time-stamp log messages using a network time
server. When enabled, you must enter the network address of the SNTP server in
the SNTP Server IP Address field.
SNTP Server IP Address: Enter the network address of the SNTP server. Valid
only when the SNTP Enable field is checked.
Time Zone (GMT): Enter the hours offset from GMT for this time zone. Valid
only when the SNTP Enable field is checked.
Syslog Enable: Check this box
feature allows AN-80i log messages to be saved in a central repository. When
enabled, you must enter the network address of the Syslog server in the Syslog
Server IP Address field.
Syslog Server IP Address: Enter the network address of the Syslog server. Valid
only when the Syslog Enable field is checked.
Ethernet Mode: Select the operating mode of the Ethernet port.
Auto - Auto-negotiate the speed connection speed.
10 - Operate at 10Base-T only.
100 - Operate at 100Base-T only.
HD - Operate at half-duplex only.
FD - Operate in full duplex only.
Important: The auto-negotiate feature does not detect the speed and duplex of
manually set Ethernet equipment. The auto-negotiate feature works correctly only
when both communicating Ethernet devices are configured for auto-negotiate.
Duplex mismatches may result in an unexpected loss of communications.
70-00072-01-01-DRAFT
to enable the SNTP protocol support. This
to enable the Syslog protocol support. This
Proprietary Redline Communications © 2006
Page 22 of 60
AN-80i
user manual
to enable flow control functions