14. INSTALLATION

14.1 Building in
The oven is designed to be connected to
230 - 240 V ~ (50 Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows:
For UK use only
Connection via
Cooker Control Cir-
cuit
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a minimum
gap of 3 mm between the switch contacts
and of a type suitable for the required load
in compliance with the current regulations.
The switch must not break the yellow and
green earth cable at any point.
WARNING!
Refer to Safety chapters.
The built-in unit must meet
the stability requirements of
DIN 68930.
Min. size cable /
flex
2,5 mm²
After installation and
connecting, the cable must
be placed so that it cannot at
any point reach a
temperature of more than
50°C above the ambient
temperature.
Before the oven is
connected, check that the
main fuse and the domestic
installation can support the
load; and that the power
supply is properly earthed.
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to the
electrical supply must comply to the
specifications given below.
Cable / flex type
PVC / PVC twin and
earth
The manufacturer declines any
responsibility should these safety
measures not be carried out.
Fuse
min: 15 A
max: 20 A