I/O Map Setting - Omron NX1P Programming Manual

Machine automation controller
Table of Contents

Advertisement

3-3-2

I/O Map Setting

Set variables for terminals.
I/O map setting means that variables used for a program are assigned to terminals (called "I/O
ports" in the Sysmac Studio) of the NX1P to which devices (I/O) are connected.
1.
Double-click I/O Map under Configurations and Setup on the Multiview Explorer. The I/O
Map is displayed.
As the NX1P is selected for the device, all input/output terminals (I/O ports: Input Bit 00 etc.)
of the NX1P are displayed in the I/O Map.
2.
Double-click an I/O port to enter a variable name.
Set variable names for input/output terminals as shown below.
Variable names for input terminals
Terminal No.
Input bit 00
Input bit 01
Input bit 02
*1. SW means a switch (Pushbutton Switch).
*2. L means a lamp (Indicator).
3.
Enter "SW1" in the Variable Column of Input Bit 00.
Variable
R/W
Data type
name
*1
R
SW1
BOOL
R
SW2
BOOL
R
SW3
BOOL
Variable names for output terminals
Variable
Terminal No.
R/W
name
Output bit 00
R
L1
Output bit 01
R
L2
Output bit 02
R
L3
Data type
*2
BOOL
BOOL
BOOL
39