Activating the infeed
To switch on the infeed, proceed as follows:
1. Click the
Activating enables
To activate the enables, proceed as follows:
1. Activate the Enables option to enable the drive.
The ON and OFF buttons
the LEDs.
Click the "Diagnostics" button to show any missing enables.
Testing the drive
To test the drive, proceed as follows:
1. Specify a speed setpoint in the n= field.
2. Use the slider to set the current speed setpoint in relation to the maximum speed
setpoint (100%).
3. Click the green switch
Or click the
you keep the switch pressed.
In the diagnostics area you can monitor the set speed/torque as well as the actual speed/
torque.
Exiting the drive control panel
To exit the drive control panel, proceed as follows:
1. Click the red button
2. Deactivate the Enables option.
The LEDs are grayed out.
3. Deactivate the infeed. To do this, click Infeed on/off.
4. Click the Return control priority button to return the control priority of the control panel.
5. On the menu bar, select Project > Disconnect from target system to switch to offline mode.
Result
The drive can be operated. The drive configuration is complete.
SIMOTION SCOUT
Configuration Manual, 11/2016
button for more information.
and
to start the drive.
switch to control the drive in jog mode. The motion continues as long as
to stop the drive.
are activated and the enable states are indicated by
Configuring/parameterizing
6.4 Configuring devices
99