Siemens SIMOTION SCOUT Configuration Manual page 157

Motion control
Table of Contents

Advertisement

Operating state
Text
SERVICE
SHUTDOWN
(empty)
Control operating state
A CPU can be switched to the designated operating state with the RUN and STOP switches.
The switching options are dependent on the position of the mode selector switch on the
SIMOTION device. The setting on the device takes priority.
Table 7-4
Mode selector switch position of the SIMO‐
TION device
STOP
STOP U
RUN
MRES
Note
As of V4.4, manual switching to the STOP U operating state is no longer possible in the SCOUT
Control operating state dialog.
If a CPU is in offline mode, both the RUN and STOP buttons are deactivated.
Simultaneous control of several CPUs
CPUs that are in online mode and that are selected in the filter column can be switched
simultaneously to the RUN or STOP operating state. To do so, click the RUN or STOP switch
below the list.
Observe that the switches only switch the CPUs that are visible in the dialog. For this reason,
check the effect of the name filter in the Target device column.
SIMOTION SCOUT
Configuration Manual, 11/2016
7.3 Controlling the operating mode with SIMOTION SCOUT
LED
(orange/white)
(orange/white)
(empty)
Switching options of the software switch dependent on the position of the mode selector
switch on the SIMOTION device.
Description
● Display, e.g. if master control has been fetched via the axis
control panel.
● Display appears only if the state persists longer 1 second.
● CPU is in offline mode
Switching option in the SCOUT "Control operating state"
dialog
STOP
STOP
RUN, STOP
STOP
Target system
157