7.2.1

Power/Sleep LED

State
Power Mode
Power Off
Non-ACPI
Power On
Non-ACPI
S5
ACPI
S1 Sleep
ACPI
S0
ACPI
Note: Blink rate is ~ 1Hz at 50% duty cycle.
7.2.2

System Status LED

Color
State
Off
N/A
Not ready
Green/
Both Solid
Not ready
Amber
On
Green
Solid on
Ok
Green
Blink
Degraded
Amber
Blink
Non-critical
Revision 1.6

Table 61. Power LED Operation

LED
Off
System power is off and the BIOS has not initialized the chipset.
Solid On
System power is on but the BIOS has not yet initialized the
chipset.
Off
Mechanical is off and the operating system has not saved any
context to the hard disk.
Blink
DC power is still on. The operating system has saved context and
gone into a level of low-power state.
Solid On
System and the operating system are up and running.

Table 62. System Status LED Operation

Criticality
Power off or BMC initialization completes if no degraded, non-
critical, critical, or non-recoverable conditions exist after power cable
plug in.
Pre DC Power On – 15-20 second BMC Initialization when AC is
applied to the server. The system will not POST until BMC
initialization completes.
System ready.
BIOS detected.
1.
Unable to use all of the installed memory (more than one DIMM
installed).
2.
In a mirrored configuration, when memory mirroring takes place
and system loses memory redundancy. This is not covered by
1
(2).
3.
PCI Express* correctable link errors.
Integrated BMC detected.
1.
One of redundant power supplies not present.
2.
CPU disabled – if there are two CPUs and one CPU is disabled.
3.
Fan alarm – Fan failure. Number of operational fans should be
more than minimum number needed to cool the system.
4.
Non-critical threshold crossed – Temperature, voltage, power
nozzle, power gauge, and PROCHOT2 (Therm Ctrl) sensors.
5.
Battery failure.
6.
Predictive failure when the system has redundant power
supplies.
Non-fatal alarm – system is likely to fail.
BIOS Detected
1.
In non-mirroring mode, if the threshold of ten correctable errors
is crossed within the window.
2.
PCI Express* uncorrectable link errors.
Integrated BMC Detected
1.
Critical threshold crossed – Voltage, temperature, power nozzle,
power gauge, and PROCHOT (Therm Ctrl) sensors.
2.
VRD Hot asserted.
3.
One of the redundant power supplies failed.