Power / Sleep Led; System Status Led; Table 42. Ssi Power Led Operation; Table 43. Control Panel Led Operation - Intel SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory Manual

Server chassis/server system
Hide thumbs Also See for SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory:
Table of Contents

Advertisement

Intel® Server System SR1550AL
7.2.1

Power / Sleep LED

State
Power Mode
Power Off
Non-ACPI
Power On
Non-ACPI
S5
ACPI
S4
ACPI
S3-S1
ACPI
S0
ACPI
Notes:
1
Blink rate is ~ 1Hz with at 50% duty cycle.
7.2.2

System Status LED

Color
State
Off
N/A
Green/
Alternating
Amber
Blink
Green
Solid on
Green
Blink
Amber
Blink
Amber
Solid on
Revision – 1.3

Table 42. SSI Power LED Operation

LED
Off
System power is off, and the BIOS has not initialized the chipset.
On
System power is on, but the BIOS has not yet initialized the chipset.
Off
Mechanical is off, and the operating system has not saved any context
to the hard disk.
Off
Mechanical is off. The operating system has saved context to the hard
disk.
Slow blink 1
DC power is still on. The operating system has saved context and
gone into a level of low-power state.
Steady on
System and the operating system are up and running.

Table 43. Control Panel LED Operation

Criticality
Not ready
AC power off
Not ready
Pre DC Power On – 15-20 second BMC Initialization when
AC is applied to the server. Control Panel buttons are
disabled until BMC initialization is complete.
Ok
System booted and ready
Degraded
System degraded
  Unable to use all of the installed memory (more than one
DIMM installed).
  Correctable errors over a threshold of 10 and migrating to
a spare DIMM (memory sparing). This indicates that the user
no longer has spared DIMMs indicating a redundancy lost
condition. Corresponding DIMM LED should light up.
  In mirrored configuration, when memory mirroring takes
place and system loses memory redundancy. This is not
covered by (2).
  Redundancy loss such as power-supply or fan. This does
not apply to non-redundant sub-systems.
  PCI-e link errors
  CPU failure / disabled – if there are two processors and
one of them fails
  Fan alarm – Fan failure. Number of operational fans
should be more than minimum number needed to cool the
system
  Non-critical threshold crossed – Temperature and voltage
Non-critical
Non-fatal alarm – system is likely to fail
  Critical voltage threshold crossed
  VRD hot asserted
  Minimum number of fans to cool the system not present
or failed
  In non-sparing and non-mirroring mode if the threshold of
ten correctable errors is crossed within the window
Critical, non-
Fatal alarm – system has failed or shutdown
  DIMM failure when there is one DIMM present, no good
recoverable
memory present
Intel order number D31982-006
Mini Control Panel
Description
Description
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr1550Sr1550al

Table of Contents