® Intel Server Board S2600TP Product Family and Intel® Compute Module HNS2600TP Product Family Service Guide A document providing instruction on installation and removal of subassemblies Revision 2.1 May 2016 Intel Server Boards and Systems...
Page 2
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family <This page is intentionally left blank.>...
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Document Revision History Revision Date Modifications Number January 2015 First Preliminary version December 2015 Applied new format May 2016 Added Intel® Xeon v4 product family references...
Page 4
This document contains information on products, services and/or processes in development. All information provided here is subject to change without notice. Contact your Intel representative to obtain the latest Service Guide.
Page 6
Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Intel warranties that this product will perform to its published specifications. However, all computer systems are inherently subject to unpredictable system behavior under various environmental and other conditions.
Intel® Compute Module HNS2600TP. This document provides a brief overview of the features of the Intel® Compute Module HNS2600TP, a list of accessories or other components you may need, troubleshooting information, and instructions on how to add and replace the components on the Intel®...
Installing an IO Module..............................23 2.8.2 Removing an IO Module ............................... 24 Installing the M.2 Device .............................. 25 2.10 Installing and Removing the Intel® Remote Management Module 4 Lite (RMM4 Lite) ....... 26 2.10.1 Installing the Intel® RMM4 Lite ..........................26...
Page 9
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family 2.10.2 Removing the Intel® RMM4 Lite ..........................27 2.11 Installing and Removing the Intel® Storage Upgrade Key ................27 2.11.1 Installing the Intel® Storage Upgrade Key ......................27 2.11.2 Removing the Intel®...
Page 10
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family List of Figures Figure 1. Intel® Compute Module HNS2600TP ........................ 1 Figure 2. Server Board Rear Connectors ..........................4 Figure 3. HNS2600TPR/HNS2600TPFR Compute Module Back Panel Features ..........4 Figure 4.
Page 11
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 49. Removing the IOM Riser and Carrier Assembly ..................24 Figure 50. Removing the Bracket from the IOM Riser and Carrier Assembly ............. 24 Figure 51. Removing the IO Module from the IOM Riser and Carrier Assembly ..........25 Figure 52.
Page 12
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family List of Tables Table 1. Intel® Server Board S2600TP Product Family Feature Set ..............1 Table 2. Intel® Compute Module HNS2600TP Product Family Feature Set ............3 Table 3.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family 1 Product Features This chapter briefly describes the main features of the Intel® Server Board S2600TP and the Intel® Compute Module HNS2600TP Product Family. This includes illustrations of the products, a list of features, and diagrams showing the location of important components and connections.
Page 14
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Feature Description • Bridge slot to extend board I/O Internal I/O connectors/headers – Four SATA 6Gb/s signals to backplane – Front control panel signals – One SATA 6Gb/s port for SATA DOM –...
One riser card with bracket in riser slot 1 to support one PCIe* 3.0 x16 low profile card (default) • One I/O module riser and carrier kit in riser slot 2 to support an Intel® I/O Expansion Module (optional) Note: Riser slot 3 and 4 cannot be used with the bridge board installed.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 2. Server Board Rear Connectors The Intel® Compute Module HNS2600TP product family has the following back panel features. Figure 3. HNS2600TPR/HNS2600TPFR Compute Module Back Panel Features Figure 4.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family 8 pin Connector for Fan 1 2x6 pin Main Power Output Connector 8 pin Connector for Fan 2 8 pin Connector for Fan 3 Power Blade Card Edge Connector (to BIB) 40 pin Misc.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 9. Server Board Features Intel® Light-Guided Diagnostics Figure 10. Intel® Light-Guided Diagnostic LEDs – Server Board The POST Code Diagnostic LEDs on the server board change color or state (off, green, red, and amber) according to the POST sequence.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Configuration and Recovery Jumpers Jumper Name Description BMC Force Update (J7A2) If pins 2-3 are selected, the Integrated BMC Force Update Mode is enabled. These pins should be selected on 1-2 for normal system operation.
1.8.1 Intel® Remote Management Module 4 Lite The Intel® Remote Management Module 4 Lite plugs into a dedicated connector on the server board and provides additional server management functionality to the compute module. The Intel® Remote Management Module 4 Lite, together with the dedicated management port on the IOM carrier sitting in the riser slot 2 provides a dedicated web server for viewing server information and remote control of the compute module.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family 2 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the Safety Information at the beginning of this manual. Note: Whenever you service the compute module, you must first power down the server and unplug all peripheral devices and the AC power cord.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Orange line: Fan cable connection line: Mother board power cable connection Blue line: Fan control signal cable connection Figure 12. Cable Routing Removing and Installing the Air Duct Always operate your compute module with the air duct in place. The air duct is required for proper airflow within the compute module.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family 2.3.2 Installing the Air Duct Align the front end of the air duct with the hinges on both sides of the fan bracket (see letter A). Rotate the air duct (see letter B) and lower down the rear end of the air duct until the left and right side buttons are firmly in place.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 15. Removing the Processor Heatsink 2.4.2 Installing the Processor Caution: Processor must be appropriate: You may damage the server board if you install a processor that is inappropriate for your server. For a web link to the list of compatible processors, see Additional Information Software.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 17. Installing the Processor – Open the Load Plate Install the Processor. Remove the processor from its package. b) Carefully remove the protective cover from the bottom side of the CPU, taking care not to touch any CPU contacts (see letter A).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 18. Installing the Processor – Install the Processor Remove the Socket Cover. Remove the socket cover from the load plate by pressing it out. Note: The socket cover should be saved and re-used should the processor need to be removed at anytime in the future.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family 2.4.3 Installing the Processor Heatsink Caution: The processor heatsink for CPU1 and CPU2 is different. FXXCA91X91HS is for CPU1, while FXXEA91X91HS2 is for CPU2. Mislocating the heatsink will cause serious thermal damage.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Installing and Removing the Memory 2.5.1 Installing the Memory Locate the DIMM socket. Make sure the clips at either end of the DIMM socket are pushed outward to the open position (see letter A).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 25. Removing the PCIe* Riser Assembly – Step 2 Remove the filler panel from the PCIe riser assembly. Figure 26. Removing the Filler Panel from the PCIe* Riser Assembly Insert the PCIe* add-in card into the riser slot (see letter C).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 28. Installing the PCIe* Riser Assembly – Step 1 Fasten the two screws (see letter E). Figure 29. Installing the PCIe* Riser Assembly – Step 2 2.6.2 Removing a PCIe* Add-in Card Loosen the two screws (see letter A).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 31. Removing the PCIe* Riser Assembly – Step 2 Remove the PCIe* add-in card from the riser slot (see letter C). Figure 32. Removing the PCIe* Add-in Card Insert the filler panel to the PCIe* riser assembly.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 34. Installing the PCIe* Riser Assembly – Step 1 Fasten the two screws (see letter E). Figure 35. Installing the PCIe* Riser Assembly – Step 2 Replacing the PCIe* Riser 2.7.1 Removing the PCIe* Riser...
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 37. Removing the PCIe* Riser Assembly – Step 2 Remove the PCIe* add-in card from the riser slot (see letter C). Figure 38. Removing the PCIe* Add-in Card Remove the PCIe* riser from the riser assembly bracket (see letter E) by loosening the two screws (see letter D).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 40. Installing the PCIe* Riser to the Riser Assembly Bracket Insert the PCIe add-in card into the riser slot (see letter C). Figure 41. Installing the PCIe* Add-in Card Insert the PCIe riser assembly into the riser slot 1 on the server board (see letter D).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Installing and Removing an IO Module 2.8.1 Installing an IO Module Remove the IOM riser and carrier assembly from its package. Note: The IOM riser and carrier assembly is provided as an optional accessory to HNS2600TPR and HNS2600TPFR.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 47. Removing the Filler Panel Insert the IOM riser and carrier assembly into the riser slot 2 on the server board (see letter H) and fasten the four screws (see letter I).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 51. Removing the IO Module from the IOM Riser and Carrier Assembly Install the bracket to the IOM riser and carrier assembly (see letter F) by tightening the two screws (see letter G).
Remove the Intel® RMM4 Lite from its package. Locate the RMM4 Lite connector on the server board next to the riser slot 2. Place the Intel® RMM4 Lite over the connector and match the orientation of the Intel® RMM4 Lite to that of the connector.
Remove the Intel® Storage Upgrade Key from its package. Locate the storage upgrade key connector on the server board next to the riser slot 1. Place the Intel® Storage Upgrade Key over the connector and match the orientation of the key to that of the connector.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Using the key pull tab, pull the key up until it disengages from the connector. 2.12 Replacing the Bridge Board 2.12.1 Removing the Bridge Board Remove the six screws (see letter A) on the bridge board.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 59. Installing the Bridge Board 2.13 Replacing the SAS/PCIe* SFF Combo Bridge Board 2.13.1 Removing the SAS/PCIe* SFF Combo Bridge Board Remove the six screws (see letter A) on the bridge board.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family 2.13.2 Installing the SAS/PCIe* SFF Combo Bridge Board Attach the plastic holder to the front end of the bridge board (see letter A). Insert the bridge board into the slots on the server board (see letter B).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 62. Removing the Cable Connections from the Server Board Remove the eight screws from the server board (see letter A). Lift up the server board (see letter B).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 64. Installing the Server Board Connect all cable connections to the server board. Figure 65. Connecting all Cables Install the bridge board. See Installing the Bridge Board. Install the PCIe riser assembly to the riser slot 1. See Installing the PCIe* Riser Assembly –...
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Straightly lift up the power docking board (see letter B). Figure 66. Removing the Power Docking Board 2.15.2 Installing the Power Docking Board Place the power docking board into the compute module base (see letter A).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 68. Removing the SAS/PCIe* SFF Combo Power Docking Board 2.16.2 Installing the SAS/PCIe* SFF Combo Power Docking Board Place the power docking board into the compute module base (see letter A).
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Figure 70. Removing the Fan 2.17.2 Installing the Fan Place the fan into the fan bracket. Connect the fan cable to the connector on the power docking board. Figure 71.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Varoitus: Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti. Locate the battery on the server board. Gently press the metal clip as shown to release the battery (see letter A).
The FRUSDR utility is included in the platform’s System Update Package (SUP) which can be downloaded from the Intel web site referenced above. The System Update Package will include full system update instructions.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family 3.2.1 No Access to the BIOS Setup Utility If the BIOS Setup utility is not accessible by hitting the <F2> key or other described access methods, it may be necessary to restore the BIOS default settings.
Page 51
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Option Description Change Value The plus key on the keypad is used to change the value of the current menu item to the next value. This key scrolls through the values in the associated pick list without displaying the full list.
Intel® One Boot Flash Update Utility (OFU) The Intel® One-Boot Flash Update Utility (Intel® OFU) is used to update the BIOS and firmware on the Intel® Server Boards while the operating system is running. The utility may be launched from a command prompt in either the Windows* or Linux* operating systems.
1600 Watt Max – 5459 BTU/hour 2130 Watt Max – 7268 BTU/hour Disclaimer Note: Intel ensures the unpackaged server board and system meet the shock requirement mentioned above through its own chassis development and system configuration. It is the responsibility of the system integrator to determine the proper shock level of the board and system if the system integrator chooses different system configuration or different chassis.
Intel® Server Board S2600TP and Intel® Compute Module HNS2600TP Product Family Appendix B. Regulatory and Compliance Information Refer to the Server Products Regulatory and Safety document for the product regulatory compliance reference. The document can be downloaded from http://www.intel.com/support/server.