Table 8-2. DR4000 System Event Messages
System Event Message
Replication Name Service replicator
exited for container <
variable
error <
>.
Replication data replicator exited
variable
for container <
variable
<
>.
Replication protocol version
mismatch for container <
variable
error <
>.
Replication delete cleanup failed for
variable
container <
variable
<
>.
Replication started as per schedule,
will be active until <
Replication stopped as per
schedule, will restart at <
Name Space Volume initialization
failed.
Inconsistencies found in the Name
Space volume.
System entering Maintenance
mode. The Name Space Volume log
replay failed. Contact Dell Support
for assistance.
System entering Maintenance
mode. The Name Space Volume
transaction failed.
Cannot add Name Space Volume
transaction.
Filesystem has reached the
maximum number of supported
Namespace entries.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 4 / 5 / 1 2 - F O R P R O O F O N LY
108
Troubleshooting and Maintenance
Description/Meaning or Action
Collect a diagnostics log file, and open a
variable
>
Support record with Dell Support for
assistance.
Collect a diagnostics log file, and open a
> error
Support record with Dell Support for
assistance.
Collect a diagnostics log file, and open a
variable
>
Support record with Dell Support for
assistance.
Collect a diagnostics log file, and open a
> error
Support record with Dell Support for
assistance.
Informational message. No user intervention is
variable
>.
required.
Informational message. No user intervention is
variable
>.
required.
Informational message. This should only occur
during initialization.
Please start the filesystem consistency checker.
Contact Dell Support for intervention or
assistance.
Contact Dell Support for intervention or
assistance.
The DR4000 system should correct itself. If
condition persists, reduce number of inodes, or
contact Dell Support for assistance or
intervention
Please clean up the filesystem to allow new file
and directory create operations.