Table 8-1. DR4000 System Alert Messages
Alert Message
System Chassis Alerts
Temperature probes have recorded
temperatures in the failed range.
Voltage probes have recorded
readings in the failed range.
Storage Controller <
failed.
Storage Controller <
missing.
Storage Controller <
an illegal configuration.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 4 / 5 / 1 2 - F O R P R O O F O N LY
Description/Meaning or Action
• Check the Events page in the DR4000 system
for specific temperature events and the
location of the temperature probes.
• Check the data center air conditioning,
ventilation, and system internal cooling fans for
problems.
• Ensure there is proper air flow through the
storage appliance, cleaning cooling vents as
needed.
• Check the Events page in the DR4000 system
for specific voltage events and the location of
the voltage probes.
• Check the power supplies. If there are no issues
with power supplies, have a service technician
check the DR4000 system appliance to see if it
requires servicing.
number
>
• Replace the RAID controller in the DR4000
system.
number
> is
• Reinsert or replace the RAID controller in the
DR4000 system.
number
> has
The expected number of virtual drives is
number
<
drives found was <
following:
• Run the Dell Restore Manager (RM) utility to
repair the drive configuration mismatch.
Troubleshooting and Maintenance
>, and the actual number of virtual
number
>. Perform the
93