Mitsubishi Electric MELSEC FX3U Programming Manual page 784

Melsec fx series programmable logic controllers
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Program example
In the program example shown below, the contents of extension registers R10 to R19 (sector 0) used for
setting data are reflected on extension file registers (ER) when X000 turns ON.
Program
X000
M0
Operation
Extension registers (R)
Device number Current
R2047
782
PLS
MOV
D8000
ADD
D8000
K47
FNC294
R10
RWER
MOV
D200
Setting data
value
R0
K100
R1
K105
.
.
.
.
.
.
R10
K200
R11
K215
R12
K400
.
.
Write
.
.
(when X000
.
.
turns ON)
R19
K350
.
.
.
.
.
.
R99
K1000
R100
HFFFF
.
.
.
.
.
.
HFFFF
33 Extension File Register Control – FNC290 to FNC299
M0
D200
D8000
FNC 07
WDT
K10
D8000
FNC 07
WDT
END
Setting backup data
Extension file registers
(ER)
Device number Current
value
ER0
K100
ER1
K105
.
.
.
.
.
.
ER10
K200
ER11
K215
ER12
K400
.
.
.
.
.
.
ER19
K350
.
.
.
.
.
.
ER99
K1000
ER100
HFFFF
.
.
.
.
.
.
ER2047
HFFFF
33.5 FNC294 – RWER / Rewrite to ER