System Components; User Interface - 3D Systems ProX 950 User Manual

Hide thumbs Also See for ProX 950:
Table of Contents

Advertisement

SYSTEM COMPONENTS

For system requirements, consult the

User Interface

The User Interface consists of a touchscreen located on the side
of the printer and the system status LED indicators. An E-Stop is
located above the touchscreen. See the section,
on page 18
for descriptions of the touchscreen functionality.
Emergency Stop:
A
above the touch screen. Emergency Stop immediately
disables all motion controls and Lasers and renders them
safe. After being pressed, it remains in the closed state
until it is manually returned to the open state.
B
Touchscreen:
Displays the Print3D Pro software which is
used to operate the system.
C
Buttons, Indicators, USB Ports
LED Indicators:
The LED indicators indicate the readiness
of the machine and its Lasers.
• "Laser" Blue LED
- ON, Solid
» Printhead enabled
-
OFF
» Printhead disabled or off.
• "Control" Green LED
-
ON, Solid
» Control systems are enabled. The machine is
ready for use.
-
ON, Flashing
» Machine is in BYPASS mode.
- OFF
» Control systems are not enabled. The machine is
not ready for use.
• "System" Amber LED
-
ON, Solid
» All safety and interlock systems have been
satisfied. Laser safety shutter is operational.
- OFF
» All safety and interlock systems have not been
satisfied. Laser safety shutter is not operational.
System
Enable: Once the software has been launched,
user will press the System Enable button to lock the doors
so system is ready to print a build. Use System Enable
after someone has pushed the emergency stop, when the
emergency has been cleared and user wants to resume
building.
USB:
Three standard auxiliary USB ports connected to the
control PC are be located under User Interface .
D
Chamber
Lights: This switch turns the chamber lighting
on or off.
Note: The chamber lights can be repositioned to view
specific areas as needed. Check the switch on the lights
themselves if they do not come on when you press the
button under the user interface .
3D Systems, Inc.
Facility Requirements
Software Overview
This switch is located on side panel
Guide.
A
B
C
D
D
14

Advertisement

Table of Contents
loading

Table of Contents