Parameterization
Menu / Parameter
Input/Output / Digital Output Mode
Function DO1 / DO2
DO1 Drive
italics = Parameter can only be viewed at the "Advanced" password level.
1) Parameter / menu only available for FEP500 / FEH500.
104
Value range
Pulse F / Pulse R,
Pulse F / Logic,
Pulse FR / Logic,
Logic / Logic
Passive, Active
FEX300, FEX500
Description
Select the functions for the digital outputs DO1 and
DO2.
Pulse F / Pulse R:
-
DO1 = Pulse output forward direction
-
DO2 = Pulse output reverse direction
Pulse F / Logic:
-
DO1 = Pulse output forward direction
-
DO2 = Digital output
Pulse FR / Logic:
-
DO1 = Pulse output forward and reverse
direction.
-
DO2 = Digital output
Logic / Logic:
-
DO1 = Digital output
-
DO2 = Digital output
Default setting: Pulse FR / Logic.
Important (Notice)
The function of the digital output is defined in the
menu "Logic Setup".
The digital output DO1 can be configured as an
"active" or "passive" output. For information on the
current configuration, refer to the order confirmation.
Default setting: Passive