Pulse Output Waveform - Mitsubishi FX2N-10GM Hardware / Programming Manual

Melsec-f
Hide thumbs Also See for FX2N-10GM:
Table of Contents

Advertisement

FX Series Positioning Controllers
8.1.8

Pulse output waveform

The following types of pulse waveforms are output to a drive unit.
You do not have to set the pulse output waveform using parameters. The pulse output wave-
form automatically changes in accordance with the practical frequency.
1) In the case of interpolation drive instructions (FX
When a simultaneous 2-axis drive instruction (cod01/02/03/31) is given, the following wave-
form is acquired at the operation frequency of 1 Hz to 100 kHz.
2) In the case of other drive instructions
• When the operation frequency in the FX
50%/50%.
• When the operation frequency in the FX
is fixed to 2.5 µs. Accordingly, the ON period becomes equivalent to the OFF period at
200 kHz.
• When the operation frequency in the FX
50%/50%.
Operation, Maintenance and Inspection 8
-20GM)
2N
OFF
ON
5µs(constant)
-10GM is 200 kHz to 1 Hz, the ON/OFF ratio is
2N
-20GM is 200 kHz to 101 kHz, the ON period
2N
-20GM is 100 kHz to 1 Hz, the ON/OFF ratio is
2N
8-6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx2n-20gm

Table of Contents