FX Series Positioning Controllers
PARA. 41: Division rate for multiplied result
The input pulses multiplied by the value set to PARA. 40 are divided by the value set here.
Table 4.44: Division rate for multiplied result
Multiplying factor and division rate
The number of input pulses is multiplied by the multiplying factor and divided by the division
rate as follows.
Number of input pulses entered from
manual pulse generator
*1 The dividing ratio is not available in the FX
Number of pulses input from manual pulse generator × Magnification
PARA.42: Head input No. for manual pulse generator enable (pulse input permission)
When the input No. set here is ON, the positioning unit receives the input from the manual
pulse generator.
Table 4.45: Head input No. for manual pulse generator enable
Setting for the FX
X2 to X3 (One point is occupied.)
The input No. of the manual pulse generator is fixed. However, the number of occupied points
varies depending on the setting of PARA. 39.
Table 4.46: The input No. of the manual pulse generator is fixed
Input
These input Nos.
are fixed.
Set to PARA.42
Input number following setting
PARA.42.
*1 When only one manual pulse generator is connected, it can be used for the X axis while the
specified input is OFF or for the Y axis and while the specified input is ON.
• Operation by manual pulse generators is available in the MANU mode or while the position-
ing unit is waiting for END (m02) in the AUTO mode.
While the enable signal is ON in the status in which manual pulse generators are available,
any other inputs is ignored except the MANU/AUTO changeover input.
FX
-10GM
2N
PARA. 40 (multiplying factor: 1 to 255)
×
-10GM
2N
FX
-10GM
2N
PARA.39 "1"
X00
Phase A
X01
Phase B
X02
X03
Enable (ON)
PARA. 41 (division rate: 2n)
-10GM.
2N
Setting for the FX
X2 to X67 (Two points are occupied.)
When setting PARA.39 is "2", the range becomes
X4 to X67.
PARA.39 "1"
Phase A
Phase B
Enable (ON)
Switching between the X
and Y axis. *1
Parameters 4
FX
-20GM
2N
n
2
n = 0 to 7
Number of
=
output pulses.
*1
= Number of output pulses
-20GM
2N
FX
-20GM
2N
PARA.39 "2"
X axis, Phase A
X axis, Phase B
Y axis, Phase A
Y axis, Phase B
X axis enable (ON)
Y axis enable (ON)