On an error-free white balance calibration, the result is displayed with
the message White balance OK.
An incorrect result is displayed with the message White balance Error.
If this is the case, the white balance calibration must repeated again.
After a successful white balance, proceed as follows:
➢ Remove the test target.
➢ Store the test target in a place which is protected from daylight.
➢ Ensure that the test target is not damaged, bent or soiled.

Lamp On/Off

This function is not relevant for setting up the device.
➢ On "Self Test 1" screen, press the LAMP ON / OFF button (4) to turn on
the LED lights.
The lamps switch off as soon as the button is no longer pressed.

Touch Adjust

The Touch Adjust function should only be carried out by a
technician certified by ImageAccess, as this may impair the
functionality of the device. This function is not relevant for
setting up the device.
➢ Contact Image Access technical support, see section
Technical Support starting at page 6.