Hydraulic Oil

Table 7-7. Hydraulic Oil
Hydraulic System
Operating
Temperature Range
+0° to + 180° F
(-18° to +83° C)
+0° to + 210° F
(-18° to +99° C)
+50° to + 210° F
(+10° to +99° C
NOTE:
Hydraulic oils require anti-wear qualities at least API Service
Classification GL-3, and sufficient chemical stability for mobile
hydraulic system service.
NOTE:
Aside from JLG recommendations, it is not advisable to mix oils
of different brands or types, as they may not contain the same
required additives or be of comparable viscosities.
3121618
SECTION 7 - GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
S.A.E. Viscosity
Grade
10W
10W-20, 10W30
20W-20
– JLG Lift –
OIL SAMPLING
This machine is equipped with an oil sampling valve to allow for
verification of hydraulic oil condition. Refer to the Service Manual
for Oil Sampling procedures.
Table 7-8. Mobilfluid 424 Specs
SAE Grade
Gravity, API
Density, Lb/Gal. 60°F
Pour Point, Max
Flash Point, Min.
Viscosity
Brookfield, cP at -18°C
at 40° C
at 100° C
Viscosity Index
10W30
29.0
7.35
-46°F (-43°C)
442°F (228°C)
2700
55 cSt
9.3 cSt
152
7-5