Maintenance Standstill Cleaning - JLG 1850SJ Operation And Safety Manual

Boom lift models
Hide thumbs Also See for 1850SJ:
Table of Contents

Advertisement

SECTION 4 - MACHINE OPERATION
Standstill Cleaning
Levels
Normal
0
Operation
Standstill
1
Required
Warning
2
Shut Off
3
4-14
Table 4-1. Maintenance Standstill Cleaning
Machine Hours
System Distress
Since Last
Cleaning
0-500
500-1000
1000-1100
1100-1125
Level
Continuous
>1125
Level
Blinking
SCR Cleaning
Light
Light
- -
- -
- -
0.5 Hz
Machine placed in
0.5 Hz
Idle Lock. Boom
Functions Locked
Out and Trapped in
3 Hz
– JLG Lift –
Derate
Comments
Between 500 and 1000 hours, clean-
None
ing cycle can be initiated with JLG
analyzer.
None
Engine coolant temperature must
be >40° C and DEF must be thawed
before cleaning can be initiated.
Creep and DTC
active
Contact Deutz Dealer.