Normal Measurement Normal Mode - Kanomax Climomaster S-6531-0E User Manual

6501 series multifunction anemometer
Table of Contents

Advertisement

§ 3
Normal Measurement
This is the mode that you will be in, when you first turn on the
instrument. In this mode you cannot save any data. The display is
updated every 1 second.
To move to NORMAL Mode from
another measuring mode, press
Select "1. NORMAL" and press
Selecting the Measuring Parameters
The measurement parameters can be selected in Normal Mode as
described below.
<Air Velocity Measurement Screen>
Humidity is only
available on
MODEL6531/6533.
Air temperature is
only available on
MODEL6531/6541
/6542/6533/6543/
6561
<Pressure Measurement Screen>
Pressure is only
available on
MODEL6501-B0
/-C0.
<Flow Rate Measurement Screen>
18
Normal Measurement
actoolsupply.com
'12/04/12a15:40:23 ~
0.87f
TCC1
25.3e
64.1g
'12/04/12a16:24:37 ~
0.31h
'12/04/12a16:24:37 ~
6037a
TCC1
24.9e
63.7g
DCCC3
C1050
Duct type
'12/04/12a16:24:37 ~
------a
TCC1
24.9e
DCC15
63.7g
WCCC-
HCCC-
NORMAL MODE
actoolsupply.com
NORMAL MODE
MENUaa1.NORMAL
aaaaaa2.DUCTaTYPE
aaaaaa3.CALCULATION
.
aaaaaa4.FLOWaRATE
aaaaaa5.DATAaOUTPUT
.
aaaaaa6.DATAaCLEAR
aaaaaa7.UTILITY
aaaaaa8.PRESSUREaZERO
While in Normal Mode as shown left,
the measured item can be changed by
pressing
. The item changes in the
following sequence: Pressure→Air
Rate→Air Velocity
Pressure measurement is a feature for
MODEL 6501-B0/6501-C0.
This screen is displayed on MODEL
6501-B0/-C0, which has a built-in
pressure sensor.
The selected duct type will be
displayed at the lower left of the
screen.
To select the duct type, use
while pressing
If you have not selected a duct type or your selected
duct type (number) is not available, the instrument will
not give you the flow rate reading. Make sure the duct
type is properly registered and selected. See "Getting
Started Duct Shape/Size Input" on P.16 for details.
.