Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual,
2 4 N O V E M B E R 2 0 1 5
Type parameter (Drivers » Main Contactor Menu) and turn the interlock off.
Verify that the programmer displays that the interlock is now Off. Contact your
Curtis distributor or support engineer to resolve any issues about the interlock
before continuing with the setup procedure.
Once you have verified the interlock is off, you can set up the throttle
input. The Throttle Type parameter must be set to match the type of throttle
(1–5) and wiring that you are using, as described on pages 13–17. Adjust the
Forward Deadband, Forward Max, Reverse Deadband and Reverse Max param-
eters to match the range of your throttle. The Throttle Pot value displayed on
the Monitor » Inputs menu (page 74) is useful when setting up these parameters.
For the forward and reverse directions, read the displayed throttle pot voltage
at the point when the throttle moves out of neutral and at the point just before
full throttle and enter these values for the deadband and max settings for that
direction. Set up the other parameters in the Throttle Menu as required by the
application.
You will be able to verify that your throttle settings are correct by
checking the Mapped Throttle value displayed in the Monitor » Inputs menu
(page 74) over the entire range of throttle pot movement. The value displayed
for Mapped Throttle should be = 0% through the range of throttle motion
that is considered neutral. The displayed Mapped Throttle should be = 100%
through the range of motion that is considered forward throttle max and should
be = -100% through the range considered reverse throttle max. Contact your
Curtis distributor or support engineer to resolve any issues about the throttle
setup before continuing with the setup procedure.
Brake
7
(see page 47)
If the brake function is not used by your application, set the Brake Pedal Enable
parameter = Off and Brake Type = 5.
Before the brake can be set up the interlock must be verified as Off, by
reading the Interlock value displayed in the Monitor » Inputs menu (page 74). If
the programmer indicates the interlock is On, review how you set the Interlock
Type parameter (Drivers » Main Contactor Menu) and turn the interlock off.
Verify that the Monitor Menu displays that the interlock is now Off. Contact
your Curtis customer support engineer to resolve any issues about the interlock
before continuing with the setup procedure.
Once you have verified that the interlock is off, you can set up the brake
input. The Brake Type parameter must be set to match the type of brake throttle
(1, 2, 3, 5) and wiring that you are using, as described on pages 13–17. Adjust
the Brake Deadband and Brake Max parameters to match the range of your
brake pot. The Brake Pot value (Pot2 Raw) displayed in the Monitor » Inputs
menu (page 74) is useful when setting up these parameters. Read the displayed
brake pot voltage at the point when the brake moves out of neutral and at the
point just before full brake and enter in these values for the deadband and
max settings. Set up the other parameters in the Brake Menu as required by
the application.
You will be able to verify that your brake settings are correct by checking
the Mapped Brake value displayed in the Monitor » Inputs menu (page 74 )
os
30
5 — INITIAL SETUP
89