Regen Limiting Map Menu; Fig. 13: Regen Current Limiting Map - Curtis 1232E Manual

Enhanced ac controllers for induction motors and surface permanent magnet motors
Hide thumbs Also See for 1232E:
Table of Contents

Advertisement

PARAMETER
Nominal
PL_Regen_Nominal
0x3065 0x00
Plus Delta
PL_Regen_Nominal_Plus_Delta
0x3066 0x00
Plus 2xDelta
Nominal
PL_Regen_
_Plus_2xDelta
0x3067 0x00
Plus 4xDelta
Nominal
PL_Regen_
_Plus_4xDelta
0x3068 0x00
Plus 8xDelta
Nominal
PL_Regen_
_Plus_8xDelta
0x3069 0x00
Fig. 13
Regen
current limiting map
(two examples).
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual,
2 4 N O V E M B E R 2 0 1 5
3 — PROGRAMMABLE PARAMETERS:

REGEN LIMITING MAP MENU

ALLOWABLE
RANGE
0 – 100 %
Sets
0 – 32767
0 – 100 %
Sets
These parameters define the percentage of regen current
0 – 32767
limit or braking current limit that will be applied at the speeds
defined by the nominal speed and delta speed parameters.
The curve can be shaped to limit the available torque at
0 – 100 %
Sets
various speeds. One possible use is to compensate for the
0 – 32767
torque-speed characteristic of the motor.
0 – 100 %
Sets
0 – 32767
0 – 100 %
Sets
0 – 32767
NOMINAL
100
80
60
NOMINAL
40
20
0
DESCRIPTION
VEHICLE SPEED (rpm)
30
os
Regen Limiting Map Parameters
43