I/O Signal Specifications

Position feedback input: sin/cos sensor

Two control lines are internally configured to read a sin/cos sensor. Position
Feedback A (pin 31) provides the sine signal, and Feedback Position B (pin 32)
provides the cosine signal. The device must be set up with one sensor revolution
per mechanical revolution.

SIN/COS SENSOR INPUT SPECIFICATIONS

signal name
pin
Position Feedback A 31
Position Feedback B 32
These signal tolerances must be maintained over the controller's voltage and
temperature ranges and the vehicle's speed range. The sin/cos waveform peaks
must be away from V
dd
the timing diagram below, V
0.5 V
V
dd
V
dd
2
V
dd
2
G
nd
0.5 V
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual,
operating
input
voltage
impedance
freq
0 to 5 V
150 kΩ
500 Hz -  5 V to
for voltages
≤ 5 V;
75 kΩ
for voltages
> 5 V
and ground by at least 0.5 V. In the example shown in
= 5 V.
dd
360° mechanical (1 cycle)
90°
V
A
V
B
max
protected
esd
.
voltage
tolerance
±  8 kV
(MaxV + 10 V) (direct strike)
V
pp
30
os