Motor: 1-Spm: Characterization Tests Menu - Curtis 1232E Manual

Enhanced ac controllers for induction motors and surface permanent magnet motors
Hide thumbs Also See for 1232E:
Table of Contents

Advertisement

3 — PROGRAMMABLE PARAMETERS:
PARAMETER
Test Enable
SPM_AutoChar_Test_Enable
0x3862 0x00
Test Throtte
Test_Throttle
0x3034 0x00
Max Test Speed
SPM_AutoChar_Max_Test_Speed
0x38C1 0x00
Max Test Current
SPM_AutoChar_Max_Test_Current
0x38C2 0x00
60
2 4 N O V E M B E R 2 0 1 5
Motor Parameters

MOTOR: 1-SPM: CHARACTERIZATION TESTS MENU

ALLOWABLE
RANGE
0 – 1
This parameter is used to start the SPM motor characterization
procedure. See section 6b for the complete description of the
0 – 1
SPM motor characterization procedure.
-1 – 1
This parameter is used to verify the direction of the motor during
-1 – 1
SPM motor characterization.
See section 6b for the complete description of the SPM
motor characterization procedure and how this parameter is used.
500 – 6000 rpm
This parameter is used to set the maximum motor speed
500 – 6000
allowed during SPM motor characterization.
See section 6b for the complete description of the SPM
motor characterization procedure and how this parameter is
used.
10 – 30 %
This parameter is used to set the maximum motor current
3277 – 9831
allowed during SPM motor characterization.
See section 6b for the complete description of the SPM
motor characterization procedure and how this parameter is
used.
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual,
DESCRIPTION
30
os

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1234e1234se1236e1236se1238e1232se

Table of Contents