Chapter 3 - Operation and AdministrationSpectrum Analyzer
Chapter 3: Operation and Administration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Calculated Tx Power equals the Radio Cluster's Tx Power.
3.10.2.2
RH Status Mask
This parameter is read-only. This parameter is a decimal number representing the value of a 32-bit mask (bits 0–31)
indicating possible failures. This parameter applies only for an installed and associated RH. For a No Failure status, the value
is 0. If the value is other than 0, contact Customer Support.
3.11

Spectrum Analyzer

Spectrum Analyzer functionality was built for the installer and the radio planner to decide for each sector, once deployed, the
best RF channel to define for the BreezeCOMPACT. This function is critical in unlicensed spectra, such as in 3.65 GHz – 3.7
GHz in the US and Canada, where other transmitting devices may interfere with the BreezeCOMPACT.
The Spectrum Analysis feature enables you to determine the noise characteristics per channel. This enables the construction
of a relatively noise-free working environment. When the Spectrum Analyzer feature is activated, the unit enters a passive
scanning mode for a period of time during which information is gathered. The scanned channels are the channels comprising
a selected subset.
Upon activating the spectrum analysis, the unit automatically shuts down the RF ports. During the information-gathering
period, the unit does not receive nor transmit data. It also cannot synchronize/associate, meaning that it cannot be managed
via the wireless link. At the end of the period, the user should configure the system for normal operation.
3.11.1

Enable/Disable

By entering the BS number (Sector 1 or Sector 2), the user can disable or enable Spectrum Analyzer functionality. Upon
enabling the function, the Tx ports stop transmitting.
3.11.2

Configuration

The Spectrum Analyzer Configuration menu includes the following options:
1 – Show Scan Configuration: Displays the current Spectrum Analyzer configuration
2 – Set Active BS Number
3 – Set Start Scanning Frequency
4 – Set Stop Scanning Frequency
5 – Set Scanning Step
6 – Set Scanning Duration Per Step
7 – Repeat
BreezeCOMPACT System Manual
BreezeCOMPACT System Manual
Spectrum Analyzer
96