Chapter 3 - Operation and AdministrationGPS Menu
Chapter 3: Operation and Administration
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.9.1.8
Stop TX After Hold Over Timeout
This parameter applies only when the External 1 PPS is enabled. It indicates whether the BTS should stop data transmission
if the unit does not receive an external 1 PPS signal and the holdover passed timeout has occurred. When enabled, the BTS
stops transmitting after being in a holdover state for more than the Hold Over Passed Timeout.
The default is Enable.
3.9.1.9
Time Zone Offset From UTC
The offset of the local time from the UTC.
The range is -12:00 to +13:00, in 30 minutes resolution. The default is +00.00.
3.9.1.10
Local Time and Date
A read-only display of the local date and time (using a 24-hour clock), as calculated using the UTC Time and Date and
taking into account the Time Zone Offset From UTC and Daylight Saving Time parameters. The format is: hh:mm:ss;
dd/mm/yyyy.
3.9.1.11
Daylight Saving Mode
The Daylight Saving Mode parameter is used to enable or disable the daylight-savings feature using the following
parameters: Start Date, Stop Date and Advance Hour Factor. The default is Disable.
A change in the Daylight Saving Mode takes effect after the next reset.
3.9.1.12
Advance Hour Factor
When Daylight Saving is enabled, this parameter defines the amount of time by which the clock should be advanced during
the daylight-saving period.
The available values are 0 (daylight saving disabled), 1 and 2 (hours). The default is 0.
3.9.1.13
Start Date
When Daylight Saving is enabled, this parameter defines the date for starting the daylight-savings feature. At the beginning
of this date (midnight of this day), the clock is advanced by the number of hours specified by the Advance Hour Factor
parameter.
Use the format dd.mm to define the date and month at which to start activating the daylight-savings feature.
A change in the Start Date takes effect after the next reset.