Proper Use; Transport And Storage; Handling And Positioning - BONFIGLIOLI Vectron Manual

Active cube expansion module em-res-03 230 v/400 v
Table of Contents

Advertisement

1.2
Warning! The frequency inverters are electrical drive components intended for in-
1.3
Transport and storage are to be done appropriate in the original packing. Store the
units only in dry rooms, which are protected against dust and moisture and are sub-
jected to little temperature deviations only. Observe the climatic conditions according
to standard EN 50178 and to the information on the label of the original packing. The
duration of storage without connection to the admissible reference voltage may not
exceed one year.
1.4
Warning! Damaged or destroyed components may not be put into operation be-
The frequency inverters are to be used according to the documentation, the directives
and the standards. Handle carefully and avoid mechanical overload. Do not bend the
components or change the isolation distances. Do not touch electronic components or
contacts. The devices contain construction elements with a risk of electrostatic, which
can easily be damaged by improper handling. Any use of damaged or destroyed com-
ponents shall be considered as a non-compliance with the applicable standards. Do
not remove any warning signs from the device.
10/07
10/07

Proper use

stallation in industrial plant or machines. Commissioning and start of in-
tended operation are not allowed until it has been established that the
machine corresponds to the provisions of the EC machine directive
98/37/EEC and EN 60204. According to the CE sign, the frequency invert-
ers additionally fulfill the requirements of the low-voltage directive
73/23/EEC and the standards EN 50178 / DIN VDE 0160 and EN 61800-2.
Responsibility for compliance with the EMC directive 89/336/EEC is with
the user. Frequency inverters are available in a limited way and as com-
ponents exclusively intended for professional use within the meaning of
the standard EN 61000-3-2.
With the issue of the UL certificate according to UL508c, the requirements
of the CSA Standard C22.2-No. 14-95 have also been fulfilled.
The technical data and the information on connection and ambient condi-
tions stated on the rating plate and the documentation must be complied
with. The instructions must have been read and understood before start-
ing work at the device.

Transport and storage

Handling and positioning

cause they may be a health hazard.
EM-RES-03
EM-RES-03