Reading parameters:
Client
Ctrl. byte
Server
Ctrl. byte
uint/int
long
Server
Ctrl. byte
The error code is stated in byte 4 in a faulty reading process.
(see Table, failure codes).
Errors marked in the table are generated by the field bus side, not in the Abort SDO
Transfer of the system bus.
30
30
Server
SDO Upload (expedited)
0
1
Parameter number
0x40
LSB
Client
Upload Response
0
1
Parameter number
LSB
0x42
Client
Abort SDO Transfer
0
1
Parameter number
LSB
0x80
Code
1
inadmissible parameter figure
2
inadmissible data set
3
parameter not readable
4
parameter not writable
5
reading error EEPROM
6
writing error EEPROM
7
checksum error EEPROM
8
parameter cannot be written during running drive
9
values of the data sets differ
10
parameter of wrong type
11
unknown parameter
12
BCC error in VECTRON bus protocol
15
unknown error
20
system bus subscriber not available only in access via
field bus connection
21
string parameter not admissible only in access via VEC-
TRON bus protocol
2
3
Data set
MSB
0xnn
Reading process free of errors
2
3
Data set
MSB
0xnn
LSB
LSB
LSB
Reading process faulty
2
3
Data set
MSB
0xnn
Code
failure codes
Description
EM-RES-03
EM-RES-03
4
5
6
Data
0
4
5
6
Data
MSB
0x00
...
...
4
5
6
Data
0
0
7
7
MSB
0x00
MSB
7
0
10/07
10/07