The Handle Housing - Stihl MS 200 Service Manual

Hide thumbs Also See for MS 200:
Table of Contents

Advertisement

1
– Remove the filter base, b 14.1.1
: Disconnect the short choke rod
(1) from the carburetor.
2
– Pull out the carburetor and
disconnect the short throttle rod,
b 14.2.1
: Disconnect the short throttle rod
(1) and pull the double throttle
lever (2) out of the handle
housing.
– Check the individual parts and
replace if necessary.
80
1
– Position the double throttle lever
so that its outer curvature is
facing the carburetor.
: Push the double throttle lever (1)
into the bore (arrow).
1
: Attach the short throttle rod
(arrow) to the double throttle
lever.
– Push the carburetor into positon
and attach the short throttle rod,
b 14.2.1
: Attach the short choke rod
(arrow) to the carburetor and
insert it into the handle housing.
1
: Push the double choke lever (1)
into the bore and the short choke
rod.
1
– Line up long choke rod (1) in the
vertical position.
– Hold the double choke lever
steady.
: Push the long choke rod (1) into
the double choke lever and turn it
clockwise until it is seated in the
guide (arrow).
1
: Push the long choke rod (1) into
the choke lever (arrow).
MS 200, MS 200 T

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms 200 t

Table of Contents