: Pry out the grommets (arrows).
– Pull the wiring harness out of the
guide on the underside of the
handle housing.
1
: Pull the wiring harness (1) out of
the holes (arrows).
– Check the wiring harness and
grommets and replace if
necessary.
A faulty ground wire may impair or
prevent operation of the short circuit
wire.
Perform the contact and continuity
test on the ground wire too.
56
1
– Turn the handle housing over.
– Pull out the cover's tab (arrow).
– Inspect the cover and replace if
necessary, b 12.4
: Push the contact spring (1) off the
peg and remove it.
: Push the contact spring (1) into
the opening (arrow).
1
– Turn the handle housing over.
: Push the contact spring (1) on to
the peg as far as stop.
– Push the cover's tab into the
opening (arrow) until it is properly
seated – this secures the contact
spring in position.
2
1
– Slip the large grommet (1) over
the wiring harness (2).
: Push the wiring harness (2),
protective tube first, into the bore
(arrow).
1
– Slip the small grommet (1) over
the short circuit wire (2).
: Push the short circuit wire, round
terminal first, through the bore
(arrow).
MS 200, MS 200 T
1
2

Hide quick links: