Powerware 5110 UPS
UserÊs manual
1
UserÊs Manual 350-1500VA

Advertisement

Table of Contents
loading

Summary of Contents for Eaton Powerware 5110

  • Page 1 Powerware 5110 UPS UserÊs manual UserÊs Manual 350-1500VA...
  • Page 2 ©2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care has been taken to ensure the accuracy of the information contained in this manual, but no liability can be accepted for any errors or omission.
  • Page 3: Table Of Contents

    Powerware 5110 UPS UserÊs manual 1023922 Revision A Contents Introduction ........................4 Features ........................4 Unit inspection ......................4 Safety Instructions ...................... 5 Battery connection required before use! ..............6 Connecting the Battery: .................... 6 Installation and Operation: ..................6 Indicators: ........................
  • Page 4: Introduction

    User-replaceable batteries Unit inspection Once you have received the Powerware 5110 UPS product, you should remove and inspect the product for shipping damage. If any damage is found, please notify the carrier and your dealer. Please keep the shipping carton and the packing foam in the event the product must be returned to the factory for service.
  • Page 5: Safety Instructions

    Although the unit may be unplugged from utility power, hazardous voltage still may be present through the battery. Place the Powerware 5110 UPS indoors in an area that has adequate airflow and is free of excessive dust. Do NOT allow the UPS to be exposed to moisture, rain, excessive heat, or direct sunlight.
  • Page 6: Battery Connection Required Before Use

    Principle shown below. For detailed information how to connect, please refer to battery replacement section. Installation and Operation: The following steps explain how to connect and operate the Powerware 5110 UPS. Connect the UPS to a grounded power outlet. Note It is recommended that the battery should be charged for minimum 8 hours to ensure full charge before placing the UPS in service.
  • Page 7: Indicators

    Indicators On/Off Push Button/Test Switch One switch controls the power to your equipment and performs a self-test to detect overload or undercharged conditions. Turn on the UPS Press and hold the switch for more than one second and release the switch after the beep.
  • Page 8 3 Battery Backup and Surge Protection Outlets These 3 Australian 10 Amp output receptacles provide full time surge protection, but also provide emergency battery backup power. 3 Surge Protection Outlets These 3 Australian 10 Amp output receptacles provide full time protection from surge and spike. Phone/Modem/ADSL Protection Built in RJ11 jacks protect the internet, phone or fax line from surges.
  • Page 9: Indicator Table

    Indicator Table Status Indicators The UPS provides both visual and audible status indicators. Visual indicators consist of three LEDs to represent the following conditions: On utility power operation On battery power operation UPS fault/alarm LED Indicator Table On Utility (AC mode) Green Lighting On Battery (backup mode) Yellow Lighting...
  • Page 10 5Ah battery (350VA, 500VA models) 7Ah x 1 battery (700VA models) UserÊs Manual 350-1500VA...
  • Page 11 7Ah x 2 batteries (1000VA models), 9 Ah x 2 batteries (1500VA models) UserÊs Manual 350-1500VA...
  • Page 12: Troubleshooting

    Battery might need to be changed, look at battery replacement Refer to the Indicator Table The „Battery Backup & „Powerware 5110 UPS is making a Surge Protection‰ outlets are continuous sound and the Overload overloaded. indictor is lit‰...
  • Page 13: Specification

    Specification*: Capacity 350VA/210W 500VA/300W 700VA/420W 1000VA/600W 1500VA/900W Dimensions (mm) HxWxD 270x87x260 270x87x260 270x87x260 270x87x384 270x87x384 Unit Weight (kg) 12.5 Input Connection 1.8 metre line cord IEC to Australian 10Amp Plug Output Connection 6 Australian 10Amp Outlets (3 Battery Backup & Surge Protection, 3 Surge Protection only) Operation Input Voltage Range...
  • Page 14 UserÊs Manual 350-1500VA...