1.
Enter system view.
2.
Configure the detection timer.

Configuring temperature thresholds

Set the temperature thresholds to monitor chassis temperature changes.
The temperature thresholds include a low temperature threshold, a warning temperature threshold, and an
alarming temperature threshold.
When the sensor temperature of the switch drops below the low temperature threshold or reaches
the warning threshold, the switch logs the event and outputs a log message and a trap.
When the sensor temperature reaches the alarming threshold, the system constantly outputs log and
tap messages.
Follow these steps to configure temperature thresholds for an IRF member switch:
Task...
1.
Enter system view.
2.
Configure
thresholds for an IRF
member switch.
Table 11 Default temperature threshold
Switch model
A5830AF-
48G(JC691A)
/ A5830AF-
48G TAA
(JG316A)
A5830AF-
96G(JC694A)
/ A5830AF-
96G
TAA(JG374A)
Command...
system-view
shutdown-interval time
Command...
system-view
temperature
temperature-limit slot slot-number
hotspot sensor-number lowerlimit
warninglimit [ alarmlimit ]
Airflow
Sensor
direction
power-to-port
1
port-to-power
1
power-to-port
1
port-to-power
1
Remarks
Optional.
The detection interval is 30
seconds by default.
Remarks
Optional.
The default temperature thresholds
depend on the airflow direction (see
Table
The warning and alarming thresholds
must be higher than the low
temperature threshold.
The alarming threshold must be higher
than the warning threshold.
Low
Warning
temperature
temperature
threshold
threshold
0°C (32°F)
70°C (158°F)
0°C (32°F)
80°C (176°F)
0°C (32°F)
60°C (140°F)
0°C (32°F)
60°C (140°F)
125
11).
Alarming
temperature
threshold
87°C (188.6°F)
97°C (206.6°F)
77°C (170.6°F)
77°C (170.6°F)