Method I—Press the Enter key directly after the command keywords, enter the banner information,
and end with the % character. The % character is not part of the banner information. For example,
configure the banner "
<System> system-view
[System] header shell
Please input banner content, and quit with the character '%'.――System prompt
Have a nice day.
Please input the Password!%
Method II—Enter a character after the command keywords at the first line, and then press Enter.
Enter the banner information, and end with the character you entered at the first line. The start
character and the end character are not part of the banner information. For example, configure the
banner "
<System> system-view
[System] header shell A
Please input banner content, and quit with the character 'A'.――System prompt
Have a nice day.
Please input the Password!A
Method III—Enter multiple characters after the command keywords at the first line (with the first and
last characters being different), and then press Enter. Enter the rest banner information, and end
with the first character you entered at the first line. The first entered character at the first line and the
end character are not part of the banner information. For example, configure the banner "
nice day. Please input the Password!
<System> system-view
[System] header shell AHave a nice day.
Please input banner content, and quit with the character 'A'.――System prompt
Please input the Password!A

Configuration procedure

Task...
Enter system view
Configure the login banner
Configure the legal banner
Configure the shell banner
Configure the MOTD banner
Configuring the software exception handling
method
Configure the switch to handle software exceptions in one of the following methods:
reboot—The switch automatically reboots to recover from the error condition.
maintain—The switch stays in the error condition so collect complete data, including error messages,
for diagnosis. In this approach, you must manually reboot the switch.
Have a nice day. Please input the Password!
Have a nice day. Please input the Password
Command...
system-view
header login text
header legal text
header shell text
header motd text
!" as follows: