Configuring The Temperature Alarm Thresholds - HP 5920 series Fundamentals Configuration Manual

Hide thumbs Also See for 5920 series:
Table of Contents

Advertisement

Figure 38 Memory alarm notification and alarm-removed notification
Free memory space
To set memory thresholds:
Step
1.
Enter system view.
2.
Set free-memory
thresholds.
3.
Set the memory
usage threshold.

Configuring the temperature alarm thresholds

The device monitors its own temperature through temperature sensors. You can set a low temperature
threshold, high-temperature warning threshold, and high-temperature alarming threshold.
When the temperature drops below the low temperature threshold or reaches the high-temperature
warning threshold, the device logs the event and sends out a log message and a trap.
When the temperature reaches the high-temperature alarming threshold, the device logs the event and
notifies users by repeatedly sending log messages and by setting the LEDs on the device panel.
To configure the temperature alarm thresholds:
Step
1.
Enter system view.
Normal
Minor
alarm
Minor
Severe alarm
Severe
Critical alarm
Critical
Command
system-view
memory-threshold [ slot slot-number ]
minor minor-value severe severe-value
critical critical-value normal normal-value
memory-threshold usage
memory-threshold
Command
system-view
152
Minor alarm-removed
Severe alarm-removed
Critical alarm-removed
Remarks
N/A
The defaults are as follows:
Minor alarm threshold—96 MB.
Severe alarm threshold—64 MB.
Critical alarm threshold—48 MB.
Normal state threshold—128
MB.
By default, the memory usage
threshold is 100%.
Remarks
N/A
Time