Eaton EMR-5000 Installation, Operation And Maintenance Manual page 994

Motor relay
Table of Contents

Advertisement

Name
Bkr.CES Disturbed
Bkr.CES Fail TripCmd
Bkr.CES SwitchgDir
Bkr.CES CLOSE d OPEN
Bkr.CES SG not ready
Bkr.CES Field Interl
Bkr.CES SG removed
Bkr.TripCmd
Bkr.Ack TripCmd
Bkr.Bwear Slow Breaker
Bkr.Res Bwear Sl Breaker
Bkr.CLOSE Cmd
Bkr.OPEN Cmd
Bkr.CLOSE Cmd manual
Bkr.OPEN Cmd manual
Bkr.CinBkr-52a-I
Bkr.CinBkr-52b-I
Bkr.Ready-I
Bkr.Ack TripCmd-I
Bkr.Interl CLOSE1-I
Bkr.Interl CLOSE2-I
Bkr.Interl CLOSE3-I
Bkr.Interl OPEN1-I
Bkr.Interl OPEN2-I
Bkr.Interl OPEN3-I
Bkr.SC CLOSE-I
Bkr.SC OPEN-I
Bkr.Operations Alarm
Bkr.Isum Intr trip: IA
Bkr.Isum Intr trip: IB
Bkr.Isum Intr trip: IC
Description
Signal: Command Execution Supervision: Switching Command unsuccessful. Switchgear in disturbed
position.
Signal: Command Execution Supervision: Command execution failed because trip command is pending.
Signal: Command Execution Supervision respectivly Switching Direction Control: This signal becomes true, if
a switch command is issued even though the switchgear is already in the requested position. Example: A
switchgear that is already OPEN should be switched OPEN again (doubly). The same applies to CLOSE
commands.
Signal: Command Execution Supervision: CLOSE Command during a pending OPEN Command.
Signal: Command Execution Supervision: Switchgear not ready
Signal: Command Execution Supervision: Switching Command not executed because of field interlocking.
Signal: Command Execution Supervision: Switching Command unsuccessful, Switchgear removed.
Signal: Trip Command
Signal: Acknowledge Trip Command
Signal: Slow Breaker Alarm
Signal: Resetting the slow breaker alarm
Signal: CLOSE command issued to the switchgear. Depending on the setting the signal may include the
CLOSE command of the Prot module.
Signal: OPEN command issued to the switchgear. Depending on the setting the signal may include the OPEN
command of the Prot module.
Signal: CLOSE Cmd manual
Signal: OPEN Cmd manual
Module Input State: Feed-back signal of the Bkr (52a)
Module Input State: Feed-back signal of the Bkr. (52b)
Module Input State: Breaker Ready
State of the module input: Acknowledgment Signal (only for automatic acknowledgment). Module input signal
State of the module input: Interlocking of the CLOSE command
State of the module input: Interlocking of the CLOSE command
State of the module input: Interlocking of the CLOSE command
State of the module input: Interlocking of the OPEN command
State of the module input: Interlocking of the OPEN command
State of the module input: Interlocking of the OPEN command
State of the module input: Switching CLOSE Command, e.g. the state of the Logics or the state of the digital
input
State of the module input: Switching OPEN Command, e.g. the state of the Logics or the state of the digital
input
Signal: Service Alarm, too many Operations
Signal: Maximum permissible Summation of the interrupting (tripping) currents exceeded: IA
Signal: Maximum permissible Summation of the interrupting (tripping) currents exceeded: IB
Signal: Maximum permissible Summation of the interrupting (tripping) currents exceeded: IC
www.eaton.com
EMR-5000
IM02602012E
994