Configuring The Cfm Domain - Cisco Catalyst 4500 Series Software Configuration Manual

Cisco ios xe release 3.9.xe and cisco ios release 15.2(5)ex
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Configuring Ethernet CFM

Configuring the CFM Domain

To configure the Ethernet CFM domain, configure a service to connect the domain to a VLAN, or
configure a port to act as a MEP, perform this task. You can also enter the optional commands to
configure other parameters, such as continuity checks.
Command
Step 1
configure terminal
Step 2
ethernet cfm ieee
Step 3
ethernet cfm global
Step 4
ethernet cfm traceroute cache [size entries |
hold-time minutes]
Step 5
ethernet cfm mip auto-create level level-id
vlan vlan-id
Step 6
ethernet cfm mip filter
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
75-8
CFM Unicast packets (Loopback Messages and Traceroute Reply), are not allowed on Down MEP
on STP blocked ports. The blocked port cannot respond to ping and traceroute. You must configure
a port MEP at a lower level than any service (VLAN) MEPs on an interface.
An 802.1Q (QinQ) tunnel port can be an Up MEP or a port MEP.
A QinQ port cannot be a Down MEP or a MIP; you can configure the port as a MIP, but it is not
active or visible in traceroute. Port MEP frames received on a QinQ interface are not tunneled and
are processed locally.
CFM on a C-VLAN is supported on Traditional and Selective QinQ and not supported on
One-to-One VLAN Mapping on Trunk ports.
Do not configure a port with tunnel mode using the native VLAN as the S-VLAN or the C-VLAN.
For port MEP on a QinQ port, do not enter the vlan dot1q tag native global configuration command
to enable tagging on native VLAN frames.
If you are running CFM draft 1 and upgrade to a software version that supports CFM draft 8.1, the
switch silently drops the draft 1 configuration on draft 8.1 image. Some of the CLIs have been
changed from draft1 to draft8.1. You need to reconfigure all the required configurations on draft 8.1
image.
Chapter 75
Purpose
Enter global configuration mode.
A must have configuration for draft 8.1. This is required to
be configured before any other configuration.
Globally enable Ethernet CFM on the switch.
(Optional) Configure the CFM traceroute cache. You can
set a maximum cache size or hold time.
(Optional) For size, enter the cache size in number of
entry lines. The range is from 1 to 4095; the default is
100 lines.
(Optional) For hold-time, enter the maximum cache
hold time in minutes. The range is from 1 to 65535; the
default is 100 minutes.
(Optional) Configure the switch to automatically create
MIPs for VLAN IDS that are not associated with specific
maintenance associations at the specified level. The level
range is 0 to 7.
Note
Configure MIP auto-creation only for VLANs that
MIPs should monitor. Configuring for all VLANs
can be CPU and memory-intensive.
(Optional) Enable MIP filtering, which means that all CFM
frames at a lower level are dropped. The default is disabled.
Configuring Ethernet OAM and CFM

Advertisement

Table of Contents
loading

Table of Contents