Cisco Catalyst 4500 Series Software Configuration Manual page 1932

Cisco ios xe release 3.9.xe and cisco ios release 15.2(5)ex
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Alert Group Trigger Events and Commands
Table 77-3
Call Home Alert Groups, Events, and Actions (continued)
Call Home
Alert Group
Trigger Event
POWER_FAIL
URE
POWER_FAIL
URE
POWER_FAIL
URE
POWER_
RECOVERY
FANTRAY_FA
ILURE
FANTRAY_FA
ILURE
FANTRAY_FA
ILURE
FANTRAY_
RECOVERY
FANTRAY_
FAILURE
CLOCK_ALA
RM
CLOCK_ALA
RM
Inventory
INSERTION
REMOVAL
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
77-20
Syslog Event
Severity Description and CLI Commands Executed
InlinePowerSupplyBad
3
MixedPowerSupplyInC
3
hassis
NotEnoughPowerChass
6
is
InlinePowerSupplyGoo
3
d
FanTrayPartialFailure
3
FanTrayMismatch
3
FanTrayBad
5
FanTrayGood
3/5
InsufficientFantray
6
ClockSwitchover
2
Clock Faulty
3
Module
1
Module
1
Chapter 77
Inline power source from a power supply has failed or
turned off.
Mixed power supplies have been detected in the
chassis.
There is insufficient power to support the system. The
system might shut down.
A failed source for inline power has been fixed.
Either a fan or thermistors in system fan tray has
failed.
The fantray, supervisor, chassis combination is
disallowed.
Fan tray has failed.
Failed fan tray has been fixed.The severity of the
notification depends on the failure which has been
recovered from.
There are not enough FanTray to support the system.
This may be followed by a system shut down.
Clock module has switched over to another clock.
The clock module has been found to be faulty.
Inventory status should be provided whenever a unit is
cold-booted, or when FRUs are inserted or removed.
it is considered a noncritical event, and the
information is used for status and entitlement.
CLI commands executed:
show module
show version
show inventory oid
show idprom all
show power
A line card or supervisor engine has been inserted into
a slot.
A line card or supervisor engine has been removed
from a slot.
Configuring Call Home

Advertisement

Table of Contents
loading

Table of Contents