Enphase Microinverter Installation

Follow the instructions in this section to install Enphase M215™ Microinverters.
WARNING: Be aware that only qualified personnel should connect the Enphase
Microinverter to the utility grid.
WARNING: Be aware that installation of this equipment includes risk of electric shock.
Normally grounded conductors may be ungrounded and energized when a ground fault is
indicated.

Compatibility and Capacity

The Enphase M215 Microinverters are electrically compatible with most 60-cell PV modules. For more
information, see Technical Data page 25 of this manual.
WARNING: The M215 should be paired only with a 60-cell PV module.
Refer to the Enphase website (http://www.enphase.com/support/downloads) for a list of electrically-
compatible PV modules and approved PV racking systems. To ensure mechanical compatibility, be sure to
order the correct connector type for both microinverter and PV module from your distributor.
Electrical Compatibility
Model Number
M215-60-2LL-S22
M215-60-2LL-S22-NA
M215-60-2LL-S23
M215-60-2LL-S23-NA
M215-60-2LL-S24
M215-60-2LL-S24-NA
Voltage and Capacity
Service type
Split phase 240V
Three phase 208V
Utility service reqirements: The M215-60-2LL works only with split phase 240V service,
three phase 208V service, or 208 single phase service.
7
Works with PV Module Type
60-cell PV module
Warning: The M215-60-2LL
should be paired only with a
60-cell PV module.
Maximum number of M215s per 20 amp AC Branch Circuit
Copyright  2012 Enphase Energy
M215 Installation and Operation
PV Module Connector Type
MC-4 Type 2 Locking or
Amphenol H4 Locking
Tyco Solarlock Locking
Max M215s per AC branch circuit
17
25
SMK
141-00012 Rev 04