PARTS REQUIRED:
Roof panels may cause serious injury until securely fastened.
You must square the roof by attaching one 48 x 96" panel at
3
this time. You will use the panel's long edge as a lever to bring
your roof into square.
Place the 48 x 96" roof panel as shown with the rough side up.
Use a gauge block to ensure the panel measures 3/4" (1,9 cm)
along the length of the rafter (Fig. A) Panel should be flush with
top edge of lower installed roof panel.
Secure with two nails.
Move to the outside edge. Using the long edge of the panel as a lever move the panel side-to-side until
4
the outside long edge is at 6" (15,2 cm) measurement overhanging the outer rafter (Fig D).
Secure with two nails.
You may need to move your entire roof frame to make panel
line up with 6" overhang measurement (Fig. D).
NOTE:
Measurement from rafter edge.
6"
(15,2 cm)
Fig. D
ROOF PANELS
x1
7/16 x 48 x 96"
(1,1 x 121,9 x 244 cm)
Fig. A
(1,9 cm)
(15,2 cm)
Flush
6"
(15,2 cm)
3/4" GAUGE
BLOCK
Flush
Gauge
Block
3/4"
6"
36
x4
2" (5,1 cm)
48 x 96"
(121,9 x 244 cm)
Two Nails
Two Nails