Toolbox Menu Items; Selection Tool; Building Blocks - Resource Data Management PR0750-TDB Installation & User Manual

Intuitive mercury tdb controller
Table of Contents

Advertisement

Intuitive Mercury 6-5M Controller with TDB

Selection tool

Building blocks (right click for sub menu's)
Static Text
Zoom in/out
Shortcut block
Setting Block
Online Mode
Run Simulation
The floating toolbox also shows the current number of blocks used in the PLC program.
Selection Tool
Left click on this icon to select the "selection tool", use this (left click and hold) to move items around on the workspace (release).

Building Blocks

?
Selection of building blocks is achieved by right clicking on the icon and rolling the mouse over one of the sub menu items and then left click on
the item. Left clicking on the workspace will drop the item. Further left clicks will give more of the same item. To select another item, repeat the
procedure. Initially this icon will show
The sub-menu choices are: -
IO
o
Analog In
o
Analog Out
o
Digital In
o
Digital Out
o
Network Analogue In
o
Network Digital In
o
Pulse Input
o
GP Timer 3 Block
o
Defrost Signal
o
State Block
o
Humidistat Display Block
o
Mercury Display Block
Functional
o
Alarm Block
o
Analog Switch
o
Analog Store
o
Pulse Counter
o
D-Type Latch
o
SR Latch
o
Digital Edge Block
o
Analogue Edge Block
o
Reverse On/Off
o
Direct On/Off
o
Direct PID
o
Reverse PID
o
Levels Block
o
P to T Block
o
Comfort Block
o
Offline Indicator
Warning
Ensure that all power is
switched off before
installing or maintaining
this product

Toolbox Menu Items

"?"
until an item is selected.
Logic
o
2-AND Block
o
3-AND Block
o
4-AND Block
o
2-OR Block
o
3-OR Block
o
4-OR Block
o
NOT Block
o
XOR Block
Diagnostic
o
Analogue
Display
o
Digital Display
Revision 2.6
Mathematical
o
Add
o
Subtract
o
Multiply
o
Divide
o
Absolute
o
X Power Y
o
Min Block
o
Max Block
o
Equals Block
o
Less-Than Block
o
Greater-Than Block
o
Less-Than-Or-Equals Block
o
Greater-Than-Or-Equals Block
o
2-Average Block
o
3-Average Block
o
4-Average Block
o
Limit Block
o
In Range Block
o
Min/Max/Avg Block
o
Filter Block
o
Accumulator
o
Algebra
Custom
o
Custom Blocks
Time
o
Delay Timer
o
Pulse Timer
o
Heartbeat
o
Run On Block
o
Run Hours Block
o
Change Over Block
o
Match Date Block
o
Date Time Block
o
Summer Winter
o
Daylight Block
o
Time Block
o
Schedule Block
o
Day of Week
Page 19 of 53
www.resourcedm.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pr0751-tdbPr0760-tdbPr0761-tdb

Table of Contents