Resource Data Management PR0750-MOB Installation & User Manual

Resource Data Management PR0750-MOB Installation & User Manual

Mercury 2 & intuitive mercury mobile controller
Table of Contents

Advertisement

Mercury 2 & Intuitive Mercury Mobile
Installation & User Guide
For Products: - PR0710, PR0711, PR0720, PR0721
Resource Data Management Ltd
80 Johnstone Avenue,
Hillington Industrial Estate,
Glasgow, Scotland, G52 4NZ, UK
+44(0)141 810 2828
sales@resourcedm.com
Controller
Resource Data Management
UK OFFICE
Resource Data Management Inc
US OFFICE
100 North Sixth Street,
Suite 820C,
Minneapolis, MN 55403, USA
Tel +1 612 354 2923
Fax +1 612 208 0922
usasales@resourcedm.com
Mercury
PR0710-MOB
PR0720-MOB
Intuitive
PR0750-MOB
PR0760-MOB

Advertisement

Table of Contents
loading

Summary of Contents for Resource Data Management PR0750-MOB

  • Page 1 Controller Installation & User Guide For Products: - PR0710, PR0711, PR0720, PR0721 Resource Data Management UK OFFICE US OFFICE Resource Data Management Ltd Resource Data Management Inc 80 Johnstone Avenue, 100 North Sixth Street, Hillington Industrial Estate, Suite 820C, Glasgow, Scotland, G52 4NZ, UK Minneapolis, MN 55403, USA +44(0)141 810 2828...
  • Page 2: Table Of Contents

    Mercury 2 & Intuitive Mobile Controller User Guide Table of Contents: THE MERCURY & INTUITIVE RANGE ......................4 Variants ................................4 Compatible Displays ............................4 Configuration ..............................4 Compatible Network Interfaces ........................4 Front Display Features ............................5 Connections ............................... 5 Mercury Mk2 6-5E and 6-5M ..........................
  • Page 3 Mercury 2 & Intuitive Mobile Controller User Guide Fixing ................................19 Dimensions ..............................20 Intuitive Mercury Mounting Instructions ......................20 Cleaning ................................. 20 Disclaimer ................................. 20 Warning Ensure that all power is Revision 1.1 Page 3 of 21 switched off before installing or maintaining this product www.resourcedm.com...
  • Page 4: The Mercury & Intuitive Range

    Mercury 2 & Intuitive Mobile Controller User Guide The Mercury & Intuitive Range From Resource Data Management For Version Mob 1.0 The Mercury Mk2 Mobile controller is intended for use in refrigeration display cabinets with one or two integral compressors with each compressor having a temperature probe fitted to enable the compressor to be stopped if a set (discharge) temperature is exceeded.
  • Page 5: Front Display Features

    Mercury 2 & Intuitive Mobile Controller User Guide Description Part Number Intuitive Internal IP Network Card Interface Kit PR0770 Intuitive Internal RS485 Network Card Interface Kit PR0771 Intuitive Internal Wireless Mesh Network Card Interface Kit PR0772 Front Display Features LED’s: - Cooling (Relay 1 or 4) Fans (Relay 2)
  • Page 6: Intuitive Mercury Controller Intuitive Mercury Network Expansion Options

    Mercury 2 & Intuitive Mobile Controller User Guide Intuitive Mercury Controller Intuitive Mercury Network Expansion Options RS232 Network Card (Default) The Intuitive Mercury is supplied with an RS232 Network Card fitted as standard. Some example optional network cards are shown below IP Network Card (PR0770) Network Activity Network...
  • Page 7: Input And Output Allocation Tables

    Mercury 2 & Intuitive Mobile Controller User Guide Input and Output Allocation Tables The following tables indicate; on a controller type basis, the functions of the inputs and outputs. Also shown are the digital inputs that are derived by switching in a fixed value resistor across the input. Input / Output allocation table TYPE Integral Case...
  • Page 8: Setup Function Menu

    Mercury 2 & Intuitive Mobile Controller User Guide Setup Function Menu Explained in Explained in Display Option Display Option Paragraph Paragraph View Inputs / Outputs and Input / output table Set/view network configuration Network States Configuration PArA Set/View Parameters Set view parameters SoFt View software version Unit...
  • Page 9: Display

    Mercury 2 & Intuitive Mobile Controller User Guide This function is now complete Display From the function menu scroll to and select diSP. Press enter and one of the following values will be shown: - 0. Controller display will show the whole number and tenths value of a temperature reading. (Default) 1.
  • Page 10: Parameter Descriptions

    Mercury 2 & Intuitive Mobile Controller User Guide P-45 Def Min Time 00:00 to 99:00 01:00 mm:ss 05:00 05:00 P-46 Def Max Time 00:00 to 99:00 01:00 mm:ss 30:00 30:00 P-47 Drain Down 00:00 to 24:00 00:15 mm:ss 01:30 00:30 P-48 Recovery Time 00:00 to 99:00...
  • Page 11 Mercury 2 & Intuitive Mobile Controller User Guide P-15 Probe 5 Select This input can be used as a defrost termination probe (default) or as a monitor probe with an OT alarm level (P-28) P-16 Relay 3 mode This changes the function of relay 3 from Lights (default) to an alarm relay. The alarm relay is energised for no alarm.
  • Page 12: Relay State And Functional Operation

    Mercury 2 & Intuitive Mobile Controller User Guide P-46 Def Max Time Maximum time period allowed for defrosting if termination temperature is not reached. P-47 Drain Down A period after defrost max to allow the draining of any surplus water P-48 Recovery Time The compressor(s) is switched on at the start of this period to allow the temperature to recover to the...
  • Page 13: Relay And Screen States During Defrost

    Mercury 2 & Intuitive Mobile Controller User Guide Relay and screen states during defrost State: Pump Down Defrost Min Defrost Max Drain Down Fan Delay Recovery Screen: Def LED: RLY 1 Comp A (Defrost set to gas) RLY 1 Comp A (Defrost set to electric) RLY 1 Comp A (Defrost set to elec/cln) RLY 4 Comp B On if Reqd...
  • Page 14: Wireless Mesh Communication Module

    Mercury 2 & Intuitive Mobile Controller User Guide Wireless Mesh Communication Module RDM Wireless Mesh System, please refer to the RDM Wireless Mesh Communication Module user guide, which can be obtained from the RDM website, for information regarding connecting a controller to a Wireless Mesh network. The value shown in 485A is of the form 05-6.
  • Page 15: Mercury Switch

    Mercury 2 & Intuitive Mobile Controller User Guide IP-r To configure the communication module for IP-r, set the three rotary switches to give each controller a unique identifier. The module should then be connected to the controller and the network. In the case of an Intuitive Mercury controller where the network card is already fitted, the three rotary switches must be set when the controller is powered off, the controller should then be powered on to connect to the network.
  • Page 16: Maximum And Minimum Control Temperature

    Mercury 2 & Intuitive Mobile Controller User Guide O-12 Last Def. Ctrl Temp. -42 to 60 (-43.6 to 140) O-13 Last Def. Type 0 (None), 1 (Internal), 2 (External), 3 (Network), 4 (Display), 5 (Timed) 6 (Forced), 7 (Skipped) O-16 Alarm Relay 0 (Unused), 1 (OK), 2 (Alarm) 0 –...
  • Page 17: Fans Only "Fans

    Mercury 2 & Intuitive Mobile Controller User Guide Fans Only “FAnS” Selecting the Fans Only option will put the controller into the Fans Only state if the current state is not Fans Only. If the current state is Fans Only then the controller will change to the Normal state. Selecting this option will exit the setup menu automatically. The display will show “FAnS OnLy”...
  • Page 18: Power Requirements

    Mercury 2 & Intuitive Mobile Controller User Guide Specification Mercury Mk2 Controller Intuitive Mercury controller PR0710-MOB & PR0720-MOB PR0750-MOB & PR0760-MOB Power requirements Supply Voltage Range 100 - 240 Vac ±10% 100 - 240 Vac ±10% Supply Frequency 50 - 60 Hz...
  • Page 19: Inputs

    Mercury 2 & Intuitive Mobile Controller User Guide Inputs Input resistance: 3.01K Ohms (for PTC or NTC type probes) Input type Selectable. See: Units Comms: RS232 with flow control Switched Resistor Example Wiring Example of resistor fitted on a probe input. Connect to remote switch or relay Probe Ground Probe Signal...
  • Page 20 Mercury 2 & Intuitive Mobile Controller User Guide Dimensions Intuitive Mercury controller Intuitive Mercury Mounting Instructions Three clips fix the Intuitive Mercury securely to DIN rail. Pull each clip until it “clicks” to remove the controller. Each clip has a mounting hole to provide an alternative fixing mechanism to DIN mounting.
  • Page 21 Mercury 2 & Intuitive Mobile Controller User Guide evision History Revision Date Changes 23/01/2014 First Issue 29/01/2014 Maximum Compressor Run Time description added. P-35 “Comp Stop Both” parameter added. 17/02/2014 Warning Ensure that all power is Revision 1.1 Page 21 of 21 switched off before installing or maintaining this product...

This manual is also suitable for:

Pr0720-mobPr0760-mobPr0710-mob

Table of Contents