1 Insulate and fix the refrigerant piping and interconnection cable
as follows:
c
a
d
b
e
f
a
Gas pipe
b
Gas pipe insulation
c
Interconnection cable
d
Liquid pipe
e
Liquid pipe insulation
f
Finishing tape
2 Install the service cover.
7.10.2

To close the outdoor unit

1 Close the switch box cover.
2 Close the service cover.
NOTICE
When closing the outdoor unit cover, make sure that the
tightening torque does NOT exceed 4.1 N•m.
7.11
Finishing the indoor unit
installation
7.11.1
To fix the user interface cover to the
indoor unit
1 Make sure that the front panel is removed from the indoor unit.
See
"7.2.3 To open the indoor unit" on
2 Plug the user interface cover into the hinges.
3 Mount the front panel to the indoor unit.
7.11.2

To close the indoor unit

1 Close the switch box cover.
2 Reinstall the top plate.
3 Reinstall the front panel.
NOTICE
When closing the indoor unit cover, make sure that the
tightening torque does NOT exceed 4.1 N•m.
Installer reference guide
38
8
8.1
This chapter describes what you have to do and know to configure
the system after it is installed.
Why
If you do NOT configure the system correctly, it might NOT work as
expected. The configuration influences the following:
▪ The calculations of the software
▪ What you can see on and do with the user interface
How
You can configure the system using two different methods.
Accessing settings – Legend for tables
page 22.
You can access the installer settings using two different methods.
However, NOT all settings are accessible via both methods. If so,
the corresponding table columns in this chapter are set to N/A (not
applicable).
See also:
8.1.1
Prerequisite: The EKPCCAB kit is required.
Configuration

Overview: Configuration

Method
Configuring via the
First time – Quick wizard. When you turn
user interface
ON the user interface for the first time (via
the indoor unit), a quick wizard starts to help
you configure the system.
Afterwards. If necessary, you can make
changes to the configuration afterwards.
Configuring via the
You can prepare the configuration off-site on
PC configurator
PC and afterwards upload the configuration
to the system with the PC configurator.
See also:
the switch box" on
INFORMATION
When the installer settings are changed, the user interface
will request to confirm. When confirmed, the screen will
shortly turn OFF and "busy" will be displayed for several
seconds.
Method
Accessing settings via the breadcrumb in the
menu structure.
Accessing settings via the code in the
overview settings.
"To access the installer settings" on page 39
"8.5 Menu structure: Overview installer settings" on page 58

To connect the PC cable to the switch box

1 Connect the cable with USB connection to your PC.
2 Connect the plug of the cable to X10A on A1P of the switch box
of the indoor unit.
A1P
X10A
Description
"8.1.1 To connect the PC cable to
page 38.
Column in tables
#
Code
ERLQ004~008CA + EHVZ04+08S18CB
Daikin Altherma – Low temperature split
4P401676-1 – 2015.02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma ehvz08s18cbAltherma ehvz04s18cb

Table of Contents