Daikin Altherma ERLQ004-006-008CA Reference Manual page 99

Low temperature split
Hide thumbs Also See for Altherma ERLQ004-006-008CA:
Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
User settings
└─ Preset values
└─ Room temperature
7.4.1.1
Comfort (heating)
7.4.1.2
Eco (heating)
└─ LWT main
7.4.2.1
[8-09]
Comfort (heating)
7.4.2.2
[8-0A]
Eco (heating)
7.4.2.5
Comfort (heating)
7.4.2.6
Eco (heating)
└─ Tank temperature
7.4.3.1
[6-0A]
Storage comfort
7.4.3.2
[6-0B]
Storage eco
7.4.3.3
[6-0C]
Reheat
└─ Quiet level
7.4.4
└─ Electricity price
7.4.5.1
[C-0C]
High
[D-0C]
7.4.5.2
[C-0D]
Medium
[D-0D]
7.4.5.3
[C-0E]
Low
[D-0E]
└─ Fuel price
7.4.6
└─ Set weather dependent
└─ Main
└────────────────── Set weather-dependent heating
7.7.1.1
[1-00]
Set weather-dependent heating
7.7.1.1
[1-01]
Set weather-dependent heating
7.7.1.1
[1-02]
Set weather-dependent heating
7.7.1.1
[1-03]
Set weather-dependent heating
└─ Additional
└────────────────── Set weather-dependent heating
7.7.2.1
[0-00]
Set weather-dependent heating
7.7.2.1
[0-01]
Set weather-dependent heating
7.7.2.1
[0-02]
Set weather-dependent heating
7.7.2.1
[0-03]
Set weather-dependent heating
Installer settings
└─ System layout
└─ Standard
A.2.1.1
[E-00]
Unit type
A.2.1.2
[E-01]
Compressor type
A.2.1.3
[E-02]
Indoor software type
A.2.1.4
[E-03]
Backup heater steps
A.2.1.5
[5-0D]
BUH type
A.2.1.6
[D-01]
Preferential kWh rate
A.2.1.7
[C-07]
Unit control method
A.2.1.8
[7-02]
Number of LWT zones
A.2.1.9
[F-0D]
Pump operation mode
A.2.1.A
[E-04]
Power saving possible
A.2.1.B
User interface location
└─ Options
A.2.2.1
[E-05]
DHW operation
A.2.2.3
[E-07]
DHW tank type
A.2.2.4
[C-05]
Contact type main
A.2.2.5
[C-06]
Contact type add.
A.2.2.6.1
[C-02]
Digital I/O PCB
A.2.2.6.2
[D-07]
Digital I/O PCB
A.2.2.6.3
[C-09]
Digital I/O PCB
A.2.2.6.4
[F-04]
Digital I/O PCB
A.2.2.7
[D-04]
Demand PCB
(*5) *04/08*
(*6) *16*
Low ambient temp. for LWT main zone heating
WD curve.
High ambient temp. for LWT main zone heating
WD curve.
Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating
WD curve.
Low ambient temp. for LWT add zone heating
WD curve.
Ext. backup heat src
Solar kit
Alarm output
Bottom plate heater
Range, step
Default value
R/W
[3-07]~[3-06], step: A.3.2.4
21°C
R/W
[3-07]~[3-06], step: A.3.2.4
19°C
R/W
[9-01]~[9-00], step: 1°C
35°C
R/W
[9-01]~[9-00], step: 1°C
33°C
R/W
-10~10°C, step: 1°C
0°C
R/W
-10~10°C, step: 1°C
-2°C
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
0: Level 1
1: Level 2
2: Level 3
R/W
0,00~990/kWh
0/kWh
R/W
0,00~990/kWh
0/kWh
R/W
0,00~990/kWh
0/kWh
R/W
0,00~990/kWh
0,00~290/MBtu
8,0/kWh
R/W
-40~5°C, step: 1°C
-10°C
R/W
10~25°C, step: 1°C
15°C
R/W
[9-01]~[9-00]°C, step: 1°C
35°C
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
R/W
[9-05]~[9-06]°C, step: 1°C
45°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
R/O
0~5
0: LT split
R/O
0: 8 (*5)
1: 16 (*6)
R/O
1: Type 2
R/O
1: 1 step
R/O
1: 1P,(1/1+2)
R/W
0: No
1: Active open
2: Active closed
R/W
0: LWT control
1: Ext RT control
2: RT control
R/W
0: 1 LWT zone
1: 2 LWT zones
R/W
0: Continuous
1: Sample
2: Request
R/O
0: No (*6)
1: Yes (*5)
R/W
0: At unit
1: In room
R/W
0: No
1: Yes
R/O
0~6
1: Type 2
R/W
1: Thermo ON/OFF
2: C/H request
R/W
1: Thermo ON/OFF
2: C/H request
R/W
0~3
0: No
1: Bivalent
R/O
0~1
0: No
R/W
0: Normally open
1: Normally closed
R/W
0: No
1: Yes
R/W
0: No
1: Pwr consmp ctrl
3/8
Installer setting at variance with
default value
Date
Value
4P401673-1 - 2015.04

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma ehvz08s18cbAltherma ehvz04s18cb

Table of Contents