Daikin Altherma ERLQ004-006-008CA Reference Manual page 83

Low temperature split
Hide thumbs Also See for Altherma ERLQ004-006-008CA:
Table of Contents

Advertisement

A1P
Main PCB
A2P
User interface PCB
A3P
*
On/OFF thermostat (PC=power circuit)
A3P
*
Heat pump convector
A4P
*
Digital I/O PCB
A4P
*
Receiver PCB (Wireless On/OFF
thermostat)
A5P
Bizone PCB
A6P
Current loop PCB
A8P
*
Demand PCB
B1L
Flow sensor
DS1 (A5P)
*
DIP switch
DS1 (A8P)
*
DIP switch
E3H
Backup heater element (3 kW)
F1B
Overcurrent fuse backup heater
F1T
Thermal fuse backup heater
F1U (A4P)
*
Fuse 5 A 250 V for digital I/O PCB
F2U (A4P)
*
Fuse 5 A 250 V for digital I/O PCB
F1U (A5P)
Fuse T 2 A 250 V for PCB
F2U (A5P)
Fuse T 2 A 250 V for PCB
FU1 (A1P)
Fuse T 6.3 A 250 V for PCB
FU2 (A1P)
Fuse T 6.3 A 250 V for PCB
K1M
Contactor backup heater
K2M
Relay 3-way valve bypass
K3M
Relay 3-way valve flow
K*R
Relay on PCB
M1P
Additional zone pump
M2P
#
Domestic hot water pump
M3P
Main zone pump
M1S
Mixing 3-way valve
M2S
#
2-way valve for cooling mode
M3S
3-way valve for space heating/domestic hot
water
PHC1
*
Optocoupler input circuit
Q1DI, Q2DI
#
Earth leakage circuit breaker
Q1L
Thermal protector backup heater
Q3L
#
Safety thermostat
R1T (A1P)
Outlet water heat exchanger thermistor
R1T (A2P)
Ambient sensor user interface
ERLQ004~008CA + EHVZ04+08S18CB
Daikin Altherma – Low temperature split
4P401676-1 – 2015.02
R1T (A3P)
*
Ambient sensor On/OFF thermostat
R2T (A1P)
Outlet backup heater thermistor
R2T (A3P)
*
External sensor (floor or ambient)
R3T (A1P)
Refrigerant liquid side thermistor
R4T (A1P)
Inlet water thermistor
R5T (A1P)
Domestic hot water thermistor
R6T (A1P)
*
External indoor or outdoor ambient
thermistor
R7T (A5P)
Mixed leaving water thermistor
R1H (A3P)
*
Humidity sensor
S1S
#
Preferential kWh rate power supply contact
S2S
#
Electrical meter pulse input 1
S3S
#
Electrical meter pulse input 2
S6S~S9S
#
Digital power limitation inputs
SS1 (A4P)
*
Selector switch
TR1
Power supply transformer
X*M
Terminal strip
X*Y
Connector
* = Optional
# = Field supply
BLK
Black
BRN
Brown
GRY
Grey
RED
Red
Notes to go through before starting the unit
English
X1M
X2M
X5M
15
**
/12.2
1
14 Technical data
Translation
Main terminal
Field wiring terminal for AC
Field wiring terminal for DC
Earth wiring
Wire number 15
Field supply
Connection ** continues on page
12 column 2
Several wiring possibilities
Option
Not mounted in switch box
Wiring depending on model
PCB
Installer reference guide
83