Field settings table
Breadcrumb
Field code
Setting name
A.2.2.8
[D-08]
External kWh meter 1
A.2.2.9
[D-09]
External kWh meter 2
A.2.2.A
[D-02]
DHW pump
A.2.2.B
[C-08]
External sensor
└─ Capacities
A.2.3.2
[6-03]
BUH: step 1
A.2.3.6
[6-07]
Bottom plate heater
Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1
LWT setpoint mode
A.3.1.1.2.1
[9-01]
Temperature range
A.3.1.1.2.2
[9-00]
Temperature range
A.3.1.1.5
[8-05]
Modulated LWT
A.3.1.1.6.1
[F-0B]
Shut-off valve
A.3.1.1.7
[9-0B]
Emitter type
└────────────────── Additional
A.3.1.2.1
LWT setpoint mode
A.3.1.2.2.1
[9-05]
Temperature range
A.3.1.2.2.2
[9-06]
Temperature range
└────────────────── Delta T source
A.3.1.3.1
[9-09]
Heating
└─ Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
A.3.2.1.2
[3-06]
Room temp. range
A.3.2.2
[2-0A]
Room temp. offset
A.3.2.3
[2-09]
Ext. room sensor offset
A.3.2.4
Room temp. step
└─ Operation range
A.3.3.1
[4-02]
Space heating OFF temp
└─ Domestic hot water (DHW)
└─ Type
A.4.1
[6-0D]
└─ Disinfection
A.4.4.1
[2-01]
Disinfection
A.4.4.2
[2-00]
Operation day
A.4.4.3
[2-02]
Start time
A.4.4.4
[2-03]
Temperature target
A.4.4.5
[2-04]
Duration
└─ Maximum setpoint
A.4.5
[6-0E]
└─ SP mode
A.4.6
└─ Weather dependent curve
A.4.7
[0-0B]
Weather-dependent curve
A.4.7
[0-0C]
Weather-dependent curve
A.4.7
[0-0D]
Weather-dependent curve
A.4.7
[0-0E]
Weather-dependent curve
└─ Heat sources
4P401673-1 - 2015.04
Minimum temp (heating)
Maximum temp (heating)
Thermo On/OFF
Minimum temp (heating)
Maximum temp (heating)
Minimum temp (heating)
Maximum temp (heating)
Leaving water value for high ambient temp. for
DHW WD curve.
Leaving water value for low ambient temp. for
DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Range, step
Default value
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
R/W
0: No
1: Outdoor sensor
2: Room sensor
R/W
0~10 kW, step: 0,2 kW
3 kW
R/W
0~200 W, step: 10 W
0 W
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~55, step: 1°C
55°C
R/W
0: No
1: Yes
R/W
0: No
1: Yes
R/W
0: Quick
1: Slow
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
R/W
15~37°C, step: 1°C
25°C
R/W
37~55, step: 1°C
55°C
R/W
3~10°C, step: 1°C
5°C
R/W
12~18°C, step: A.3.2.4
12°C
R/W
18~30°C, step: A.3.2.4
30°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: 0,5 °C
1: 1 °C
R/W
14~35°C, step: 1°C
25°C (*5)
14~35°C, step: 1°C
35°C (*6)
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
R/W
0: No
1: Yes
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
R/W
0~23 hour, step: 1 hour
23
R/W
60°C
R/W
40~60 min, step: 5 min
40 min
R/W
40~60°C, step: 1°C
60°C
R/W
0: Fixed
1: Weather dep.
R/W
35~[6-0E]°C, step: 1°C
55°C
R/W
45~[6-0E]°C, step: 1°C
60°C
R/W
10~25°C, step: 1°C
15°C
R/W
-40~5°C, step: 1°C
-10°C
Installer setting at variance with
default value
Date
Value
(*5) *04/08*
(*6) *16*