Room temperature sensor – adjustable cool/warm with occupancy switch (8 pages)
Summary of Contents for Daikin Altherma EHVZ08S18CB
Page 1
User reference guide Daikin Altherma – Low temperature split EHVZ04S18CB User reference guide EHVZ08S18CB English Daikin Altherma – Low temperature split EHVZ16S18CB...
4.7.6 Predefined schedules: DHW tank temperature... 17 INFORMATION Weather dependent operation........... 18 4.8.1 To set the weather dependent settings....... 18 Indicates useful tips or additional information. User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
Latest revisions of the supplied documentation may be available on ▪ Do NOT place any objects containing water on the unit. the regional Daikin website or via your installer. NOTICE The original documentation is written in English. All other languages are translations.
INFORMATION If you press while changing settings, the changes will NOT be applied. 4.2.2 Status icons Icon Description Space operation mode = Heating. Not available. User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
1 Go to the room temperature home page (Room). To go to a home page 2 Press 1 Press Result: One of the home pages is displayed. EHVZ04~16S18CB User reference guide Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
See also: ▪ "4.4.5 Room thermostat control - Using the room temperature home page" on page 7 ▪ "To set the overrule period" on page 8 User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
1 Go to the room temperature home page (Room). ▪ Temporarily overrule the room temperature schedule by 2 Use to adjust the temperature. pressing (same as if user profile = Basic) EHVZ04~16S18CB User reference guide Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
Page 8
"4.4.3 Determining Usage example: You go away for a couple of hours which temperature control you are using" on page 6. If you are in the following situation: User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
To adjust the leaving water temperature (additional) 1 Go to the additional leaving water temperature home page (LWT add). 45°C 47°C 2 Press to adjust. Example: EHVZ04~16S18CB User reference guide Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
▪ Room temperature on the external thermostat control Check the installer settings table filled in by the installer. ▪ Leaving water temperature on the user interface (Daikin) To determine which DHW tank mode you are using (method 2) Prerequisite: User profile = Detailed.
In scheduled mode, you can do the following: Adjust the preset value (Reheat). Menu structure See also: ▪ "4.5.3 Scheduled mode" on page 11 ▪ "4.7 Preset values and schedules" on page 16 EHVZ04~16S18CB User reference guide Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
Result: The user permission level switches to End user. The user ▪ You do NOT have to change the schedule (= easy). interface will return to the default home screen. User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
▪ During the day: OFF to ensure the heating capacity of the the holiday mode is already system. running. ▪ However, during the afternoon the baby is sleeping and you want it to be quiet. EHVZ04~16S18CB User reference guide Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
▪ You want to save energy, but prevent your house from freezing. [6.7] Running hours Running hours of the system. [6.8] Version Version information about the system. Then you can do the following: User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
1 Press to go to the menu structure. 2 Press for more than 5 seconds. 3 Select a function and press 4 Select Lock or Unlock, and press EHVZ04~16S18CB User reference guide Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
1 Program 3 room temperature schedules in heating mode and give them appropriate names. Example: EarlyShift, DayShift and LateShift 2 Select the schedule that you currently want to use. User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
Note: in heating, this value should be lower than (c) as for high outdoor temperatures less warm water is required. User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
[7.4] Preset values Room temperature LWT main Tank temperature Quiet level [7.7] Set weather dependent Main [7.7.1] Main Additional Set weather-dependent heating [7.7.2] Additional Set weather-dependent heating EHVZ04~16S18CB User reference guide Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
▪ If heating up the DHW tank once at night is not sufficient, program to additionally heat up the DHW tank to a preset value (Storage eco = lower DHW tank temperature) during the day. User reference guide EHVZ04~16S18CB Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
Prerequisite: Only available if is displayed on the home pages. 1 Go to [6.3.1]: > Information > Error handling > Warning history. EHVZ04~16S18CB User reference guide Daikin Altherma – Low temperature split 4P401674-1 – 2015.02...
INFORMATION the accompanying documentation. When the backup heater takes over the heat load, Field supply electricity consumption will be considerably higher. Equipment not made by Daikin that can be combined with product according instructions accompanying documentation. Relocation...
Need help?
Do you have a question about the Altherma EHVZ08S18CB and is the answer not in the manual?
Questions and answers